Chiseling power can be reduced to approx. 70% by pressing the power level selector switch. The power
level LED then lights up, indicating reduced power.
3.6 Service indicator information
The breaker is equipped with a service indicator LED.
Status Meaning
The service indicator lights red. End of service interval servicing is due.
A fault has occurred in the tool.
The service indicator blinks red. The overheating prevention cut-out has been acti-
vated.
The voltage provided by the electric supply is too
high.
Bring the product to Hilti Service in good time. This will help to ensure that it’s always ready for use.
3.7 Items supplied
Breaker, side handle, operating instructions.
You can find other system products approved for your product at your local Hilti Center or online at:
www.hilti.group.
4 Technical data
4.1 Breaker
For details of the rated voltage, current, frequency and/or input power, please refer to the power tool’s
country-specific type identification plate.
When powered by a generator or transformer, the generator or transformer’s power output must be at least
twice the rated input power shown on the rating plate of the power tool. The operating voltage of the
transformer or generator must always be within +5% and -15% of the rated voltage of the power tool.
TE 1000AVR
Weight in accordance with EPTA procedure 01
12.5 kg
Single impact energy in accordance with EPTA
procedure 05
26 J
4.2 Noise information and vibration values in accordance with EN 62841
The sound pressure and vibration values given in these instructions were measured in accordance with a
standardized test and can be used to compare one power tool with another. They can also be used for a
preliminary assessment of exposure.
The data given represent the main applications of the power tool. However, if the power tool is used for
different applications, with different accessory tools, or is poorly maintained, the data can vary. This can
significantly increase exposure over the total working period.
An accurate estimation of exposure should also take into account the times when the tool is switched off, or
when it is running but not actually being used for a job. This can significantly reduce exposure over the total
working period.
Identify additional safety measures to protect the operator from the effects of noise and/or vibration, for
example: maintaining the power tool and accessory tools, keeping the hands warm, organization of work
patterns.
Noise emission values
Sound (power) level (L
WA
)
96 dB(A)
Uncertainty for the sound power level (K
WA
)
3 dB(A)
Emission sound pressure level (L
pA
)
85 dB(A)
Uncertainty for the sound pressure level (K
pA
)
3 dB(A)

Other manuals for Hilti TE 1000-AVR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hilti TE 1000-AVR and is the answer not in the manual?

Hilti TE 1000-AVR Specifications

General IconGeneral
Weight12.5 kg
Impact Energy26 J
Vibration ReductionYes
Tool HolderTE-S
Weight according to EPTA Procedure 01/200312.5 kg
Full hammering frequency1950 impacts/minute
Power SourceCorded Electric
Voltage230 V
Blows per Minute1950 bpm
Dust removal system availableYes
Impact Rate1950 impacts/minute