COMPONENTS AT THE REAR | PAGE 7
3. COMPONENTS AT THE REAR
The rear is where the connection terminals are found, together with a USB port
for programming parameters, consulting the alarms log and the total and partial
hour meter.
CONNECTION TERMINALS
1. Alternator voltage input 220V (GEN)
2. Pick-up input (PCK)
3. Pick-up and alternator voltage common input (GCOM)
4. Water temperature input (ATA)
5. Low oil pressure input (BPA)
6. Fuel reserve input (RC)
7. Auxiliary input (AUX)
8. External start input (LT)
9. Emergency stop input (PEM)
10. Preheating output (PR)
11. Contactor activation output (CON)
12. D+ terminal (D+)
13. Alarm output (AL)
14. Battery negative (-BAT)
15. Battery positive 12/24 (8-36V)
16. Starting output (ARR)
17. Stop by excitation (PC)
18. Stop by de-excitation (PD)
19. Power supply for power outlets (+BAT)