3.2 General Specifications
59
3.2 General Specifications
Location for use Pollution Degree 2, altitude up to 2000 m (6562-ft.)
Storage
temperature
and humidity
-20 to 60°C (-4.0°F to 140°F), 80%RH or less (non-condensation,
except for the battery)
Operating
temperature
and humidity
Temperature : -10 to 50°C (14°F to 122°F)
Humidity : 80%RH or less (non-condensation)
Dielectric strength
Between the Case and the Clamp core 7400 Vrms 1 minute
Applicable
standards
Safety : EN61010
EMC : EN61326
Effects of radiated, radiofrequency, electromagnetic field: At 3 V/m,
5X accuracy specifications or less (resistance measurement)
Dust and water
protection
IP40 (EN60529)
*With clamp sensor closed.
Power supply LR06 alkaline battery × 2 (3 VDC)
Maximum rated
power
450 mVA
Continuous
operating time
Approx. 35 hours (25 measurement, backlight off,
Bluetooth® OFF (Model FT6381), 23°C reference
Dimensions Approx. 73 W×218 H×43 D mm (2.87”W×8.58”H ×1.69”D) (exclud-
ing projections)
Maximum
measurable con-
ductor diameter
φ32 mm
Mass Approx. 620g (21.9 oz) Except for the battery
Accessories
Carrying case (1), Resistance check loop (1), Strap (1),
LR06 alkaline battery × 2, Instruction manual (1)
Display specifications
LCD display Max. 2,000 count
Display refresh
rate
Approx. 2 times/sec.
Range switching Auto-range
Overrange
display
[O.L] display
Data hold
display
mark lights up.
Pr
oduct warranty
period
3 years