EasyManua.ls Logo

Hirschmann iSCOUT expert compact - Page 48

Hirschmann iSCOUT expert compact
57 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
© 2008 HIRSCHMANN Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann-usa.com 48
50 650 19 0201e_Rev C (LinkBelt278).doc / 2008-08-18 / Rev. C / rk
Fault
code
Error Cause Elimination
E2E
Upper limit value in
measuring channel
"force derricking sys-
tem" has been ex-
ceeded.
• Refer to E14
• Refer to E14
E2F
Upper limit value in
measuring channel "SL
mast angle" has been
exceeded.
• Refer to E14
• Refer to E14
E37
Error in the logical
program flow
• System program file is defec-
tive
• Flash-EPROM defective
• Upload valid system soft-
ware
• Replace central unit
E38
System program and
crane data file do not
match.
• The system program in the LMI
does not match to the pro-
gramming in the crane data file
• Upload valid system pro-
gram file or the valid crane
data file
E39
System program and
load chart file do not
match
• The system program in the LMI
and the programming in the
load chart file do not match.
• Upload valid system pro-
gram file or the valid load
chart file
E3A
crane data file and load
chart file do not match
• Crane type in dat file and load
chart file is different
• Change dat file and/or load
chart file
E43
Error in the write/read
memory, (RAM)
• Write/read memory (RAM) or
central unit defective.
• Replace central unit
E51
Error in the crane data
file
• No valid data in the crane data
file.
• Flash-EPROM defective
• Upload valid crane data file
• Replace central unit
E52
Error in load chart file.
• No valid data in the load chart
file
• Flash-EPROM defective
• Upload valid load chart file
• Replace central unit
E56
Error in crane data file.
• No valid data in the crane data
file during calibration.
• Flash-EPROM defective
• Restore or upload valid
crane data file
• Replace central unit
E57
Error in serial crane
data file.
• Calibration data file does not
contain valid data.
• Flash-EPROM defective
• Upload calibration data file
• Replace central unit
• No valid data in the load chart
file
• Upload valid load chart file
• Base number not programmed • Program the correct base
number (1 for base 1, 2 for
base 2)
E60
The number of the
selected File base and
the programmed value
are not identical
• Load chart file programmed
wrong
• Check base programming in
the load chart file.
• CAN Bus cable between the
central unit and the sensor unit
defective or not connected.
• Check the connection be-
tween the central unit and
the sensor units
• Can bus port in the central unit
defective
• Replace the central unit
E61
Error in the CAN bus
data transfer for all
CAN units
• Short circuit in a CAN Bus
cable
• Replace Can Bus cable
E80
Error in the slewing
angle measurement
• The difference between the
average of the slewing angle
and one of the wipers of the
slewing potentiometer is out of
the tolerance
• Check the slewing potenti-
ometer adjustment
• Replace slewing angle
sensor