Troubleshooting
© 2008 HIRSCHMANN Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann-usa.com 49
50 650 19 0201e_Rev C (LinkBelt278).doc / 2008-08-18 / Rev. C / rk
Fault
code
Error Cause Elimination
E81
Too large difference of
the boom angles at tip
and base boom (if
avail.)
The angle as to the horizontal
on the boom head exceeds the
main boom angle by more than
5 degrees.
Check angle sensor on the
boom head.
Check angle sensor on the
base boom.
E82
Too large difference of
the luffing jib angles at
tip and base jib.
The angle as to the horizontal
on the jib head exceeds the luff-
ing jib angle by more than 5
degrees.
Check angle sensor on the
jib head.
Check angle sensor on the
jib base.
E83
Maximum force in the
main boom pendants
exceeded
The force actuating on the main
boom pendants has exceeded
the programmed value
Reduce force acting on the
main boom pendants.
E84
Wrong rigging condi-
tion.
The selected rigging condition
is not contained in the crane
data file.
Select another rigging con-
dition
Check the programming in
the crane data file.
E85
Error in the radius
determination
The computed radius is too
small (negative deflection)
Check the programming in
the crane data file.
E88
Faulty main boom
position during luffing
jib operation
During luffing jib operation the
main boom is not in the pre-
scribed angle range
Angle measurement of main
boom defective.
Luff boom to the permitted
range
Check angle measurement
of the main boom.
E89
Faulty positioning of
the jib during operation
with fixed angle to the
main boom or to a
luffing jib
During operation with fixed jib
to the main boom, the jib is not
in the permitted angle range
Angle measurement of the jib
defective
Luff the auxiliary jib to the
permitted range
Verify angle measurement
of the auxiliary jib.
E98
LMI watchdog acti-
vated
LMI processing time limit
exceeded
Reset system
Connect PC terminal
and watch error mes-
sages
EAB
Short circuit in the A2B
switch circuit
Short circuit in the A2B
switch
Short circuit in the cable to
the A2B switch
Replace A2B switch
Replace cable to the
A2B switch
EAC
A2B switch circuit
disconnected
Disconnected cable in the
A2B switch
Disconnected cable to the
A2B switch
Connect or replace ca-
ble in the A2B switch
Connect or replace ca-
ble to the A2B switch
EAD
No valid A2B switch
status
Sensor wrong function
CAN bus delay
Replace A2B switch
Replace cable to the
A2B switch