Troubleshooting
© 2008 HIRSCHMANN Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann-usa.com 50
50 650 19 0201e_Rev C (LinkBelt278).doc / 2008-08-18 / Rev. C / rk
Fault
code
Error Cause Elimination
EB1
Below lower limit value
in measuring channel
"rope length on the
winch”
• No rope on the winch
(* only EB1)
• No sensor for winch measuring
available
• rope length not calibrated
• wrong rope/winch parameters
in data-programming
• counter input not define in con-
figuration
• counter input defective
• calibrate rope length
• mount sensor or turn off this
function in the data-
programming
• calibrate rope length, layer
• check parameter in the
data-programming
• change I/O configuration
• change Iflex
EB2
Upper limit value in
measuring channel "
rope length on the
winch" has been ex-
ceeded.
• Rope completely rolled up on
winch (* only EB2)
• Refer to EB1
• calibrate rope length
• Refer to EB1
EB3
Upper limit value in
measuring channel
"hook height" has been
exceeded.
• No rope length between front
sheave and hook
• Refer to EB1
• Refer to EB1
EDD
Battery empty
• Battery check detected a low
voltage of the battery
• change and setup battery
• Temporary: Press alarm off
button to work without data-
logger
EFD
LMI Watchdog extra
time
• Function requires more than 0.5
seconds to activate, e.g.
write flash PROM
• Message is deactivated
automatically after process-
ing
Note:
If a fault message is displayed that is not included in the present list, then please contact
your local Hirschmann Customer Service. > www.hirschmann-
usa.com <