Ring/Network coupling
Redundanz L2P
Release
5.0
04/09
5.2
Preparing a Ring/Network coupling
75
Note: Configure the coupling port and the redundancy ring ports on different
ports.
Device Coupling port Control port
RS2-./. Port 1 Stand-by port (can only be combined
with RS2-../.. )
RS2-16M Adjustable for all ports
(default setting: port 1)
Adjustable for all ports
(default setting: port 2)
RS20, RS30,
RS40
Adjustable for all ports
(default setting: port 1.4)
Adjustable for all ports
(default setting: port 1.3)
OCTOPUS Adjustable for all ports
(default setting: port 1.4)
Adjustable for all ports
(default setting: port 1.3)
MICE Adjustable for all ports
(default setting: port 1.4)
Adjustable for all ports
(default setting: port 1.3)
Power MICE Adjustable for all ports
(default setting: port 1.4)
Adjustable for all ports
(default setting: port 1.3)
MS20 Adjustable for all ports
(default setting: port 1.4)
Adjustable for all ports
(default setting: port 1.3)
MS30 Adjustable for all ports
(default setting: port 2.4)
Adjustable for all ports
(default setting: port 2.3)
RSR20/RSR30 Adjustable for all ports
(default setting: port 1.4)
Adjustable for all ports
(default setting: port 1.3)
MACH 100 Adjustable for all ports
(default setting: port 2.4)
Adjustable for all ports
(default setting: port 2.3)
MACH 1000 Adjustable for all ports
(default setting: port 1.4)
Adjustable for all ports
(default setting: port 1.3)
MACH 3000 Adjustable for all ports Adjustable for all ports
MACH 4000 Adjustable for all ports
(default setting: port 1.4)
Adjustable for all ports
(default setting: port 1.3)
Table 11: Port assignment for the redundant coupling (two-Switch coupling with con-
trol line)
Activate the function in the “Operation” frame (see fig. 31).
You now connect the redundant line and the control line.
The displays in the “Select port” frame mean (see fig. 38):
“Port mode”: The port is either active or in stand-by mode.
“Port state”: The port is either connected or not connected.
“IP Address”: The IP address of the partner, if the partner is already
operating in the network.

Other manuals for Hirschmann RS20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann RS20 and is the answer not in the manual?

Hirschmann RS20 Specifications

General IconGeneral
MountingDIN Rail
Operating Temperature-40°C to +70°C
Protection ClassIP30
Switching TechnologyStore-and-Forward
Product TypeIndustrial Ethernet Switch
Port Details10/100 Mbps Ethernet ports
Switching Capacity3.2 Gbps
MAC Address Table8k
ManagementWeb, SNMP
RedundancyMRP