EasyManua.ls Logo

Hirschmann RS30-...U Series - Page 35

Hirschmann RS30-...U Series
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RS20/RS30...U
Release
01
06/2012
35
EMC and immunity
Network range
Note: The line lengths specified for the transceivers apply for the
respective fiber data (fiber attenuation and BLP/dispersion).
EMC compliance – IEC/EN 61000-6-2:2005 EMI TYPE tests,
test acc. to:
A
a)
B
a)
H
a)
IEC/EN 61000-4-2 Electrostatic discharge
Contact discharge
Air discharge
4 kV
8 kV
8 kV
15 kV
8 kV
15 kV
IEC/EN 61000-4-3 Electromagnetic field
80 - 3,000 MHz 10 V/m 20 V/m 20 V/m
IEC/EN 61000-4-4 Fast transients (burst)
Power line
Data line
2 kV
1 kV
4 kV
4 kV
4 kV
4 kV
IEC/EN 61000-4-5 Voltage surges
Power line, line / line
Power line, line / earth
Data line
0.5 kV
1 kV
1 kV
1 kV
2 kV
4 kV
1 kV
2 kV
4 kV
IEC/EN 61000-4-6 Line-conducted interference voltages
10 kHz - 150 kHz
150 kHz - 80 MHz
3 V
10 V
3 V
10 V
3 V
10 V
EN 61000-4-9 Impulse-shaped magnetic fields 300 A/m 300 A/m
EMC emitted interference A
a)
B
a)
H
a)
EN 55022 Class A Yes Yes Yes
FCC 47 CFR Part 15 Class A Yes Yes Yes
German Lloyd Classification + Construction Guidelines VI-
7-3 Part 1 Ed.2001
—YesYes
Stability A
a
a. Product code A: Certification = CE, UL
Product code B: Certification = CE, UL, GL, railway (along track), sub station, ATEX
Product code H: Certification = CE, UL, GL, railway (along track), sub station
(s. page 16 “Combination options for RS20/30-...U”)
B
a)
H
a)
Vibration IEC 60068-2-6 Test FC test level according
to IEC 61131-2
Yes Yes Yes
Germanischer Lloyd Guidelines for the
Performance of Type Tests Part 1
—YesYes
IEC 870-2-2 table 3 normal installation
according to EN 61850-3
—YesYes
Shock IEC 60068-2-27 Test Ea test level
according to IEC 61131-2
Yes Yes Yes
IEC 870-2-2 table 3 normal installation
according to EN 61850-3
—YesYes