Installation RSP 20/25/30/35
Release
 
15
 
12/2017
13
 IECEx – Certification Scheme for Explosive Atmospheres
For RSP devices labeled with an IECEx certificate number, the following 
applies:
List of standards: 
IEC 60079-0:2011+Cor.2012+Cor.2013
IEC 60079-15:2010
 The equipment shall only be used in an area of not more than pollution 
degree 2, as defined in IEC 60664-1.
 Make sure that the device has the following label: 
Ex nA IIC T4 Gc IECEx DEK 15.0014X
 
 
Environmental class and temperature code for RSP types:
T4: 0 °C ≤ Ta ≤ +60 °C for “S“ types or
T4: −40 °C ≤ Ta ≤ +70 °C for “T“ or “E“ types 
 The modules shall be installed in a suitable enclosure in accordance 
with IEC 60079-15 providing a degree of protection of at least IP54 
according to IEC 60529, taking into account the environmental 
conditions under which the equipment will be used.
 When the temperature under rated conditions exceeds 158 °F (70 °C) 
at the cable or conduit entry point, or 176 °F (80 °C) at the branching 
point of the conductors, the temperature specification of the selected 
cable and cable entries shall be in compliance with the actual 
measured temperature values. 
 Provisions shall be made to prevent the rated voltage from being 
exceeded by transient disturbances of more than 119 V.
 Connectors shall be connected or disconnected exclusively in dead-
voltage state.
  The USB port shall remain disconnected.