3 Making basic settings
The IP parameters must be entered when the device is installed for the first 
time. The device provides the following options for configuring IP addresses:
 Input via the V.24 interface
 Entry via the HiDiscovery protocol in the applications HiDiscovery or 
Industrial HiVision
 Configuration via BOOTP
 Configuration via DHCP (Option 82)
 AutoConfiguration Adapter
 Default settings
 IP address: The device looks for the IP address using DHCP
 Management password: 
user, password: public (read only)
admin, password: private (read/write)
 V.24 data rate: 9600 Baud
 Ethernet ports: link status is not evaluated (signal contact)
 Optical ports: Full duplex
TP ports: Autonegotiation
 RSTP (Rapid Spanning Tree) activated