Installation RSP 20/25/30/35
Release
15
12/2017
2.3.2 Grounding the device
The housing is grounded via the separate ground screw on the bottom left of
the front panel.
The device variants featuring supply voltage with characteristic value K9
and KK have a connection for protective grounding.
The device variants featuring supply voltage with the characteristic value CC
have a connection for functional grounding.
The device variants featuring supply voltage with characteristic value TT
have a connection for functional grounding.
Ground the device via the ground screw.
2.4 Installing an SFP transceiver (optional)
Use only Hirschmann SFP transceivers which are suitable for usage with the
device.
See “Accessories” on page 60.
Proceed as follows:
Remove the protection cap from the SFP transceiver.
Push the transceiver with the lock closed into the slot until it latches in.