EasyManua.ls Logo

Hitachi CP-X2011N - Page 17

Hitachi CP-X2011N
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
CP-X2511N(C15I-25N2) / CP-X3011N(C15I-30N2) / CP-X4011N(C15I-40N2) / CP-X2011N(C15-20N2) / ED-X45N(C15-20N2)
YES
YES
YES
NO
NO
2.5V or more
YES
Set the time in
DATE AND TIME on
NETWORK menu.
NO
NO
Is voltage
input at pin 1 of
EE02 on PWB assembly
MAIN when power switch
was turned
off.
Was the time set before?
DATE
AND TIME is
displayed as 2000/1/1 0:00
in INFORMATION on
NETWORK
menu.
YES
YES
NO
NO
Configure the Daylight
Saving Time in web
setting.
Is the
time adjusted by
Daylight Savings Time ?
Is TIME
DIFFERENCE on
INFORMATION correct ?
Set the time.
Is internal clock battery
old ?
Time is not correctly displayed.
PWB assembly
MAIN
PWB assembly
MAIN
PWB assembly BATTERY
Cables (CNBAT)
Use new battery.
(see 6.4)

Other manuals for Hitachi CP-X2011N