17
CP-X2511N(C15I-25N2) / CP-X3011N(C15I-30N2) / CP-X4011N(C15I-40N2) / CP-X2011N(C15-20N2) / ED-X45N(C15-20N2)
YES
YES
YES
NO
NO
2.5V or more
YES
Set the time in
DATE AND TIME on
NETWORK menu.
NO
NO
Is voltage
input at pin 1 of
EE02 on PWB assembly
MAIN when power switch
was turned
off.
Was the time set before?
DATE
AND TIME is
displayed as 2000/1/1 0:00
in INFORMATION on
NETWORK
menu.
YES
YES
NO
NO
Configure the Daylight
Saving Time in web
setting.
Is the
time adjusted by
Daylight Savings Time ?
Is TIME
DIFFERENCE on
INFORMATION correct ?
Set the time.
Is internal clock battery
old ?
Time is not correctly displayed.
PWB assembly
MAIN
PWB assembly
MAIN
PWB assembly BATTERY
Cables (CNBAT)
Use new battery.
(see 6.4)