Item Controller Drive tray
3. This table shows the power requirement (100 V or 200 V) for the maximum configur
ation .
The actual required power might exceed the value shown in the table when the tolerance is
included.
Environmental specifications
Temperature
Caution: The following VSP Gx00/Fx00 stor
age system components are not
supported in high-temperature environments. Do not operate the following
components at temperatures of 40°C or higher:
DB60 dense drive tray
HDS provided service processor (SVP) server
First-generation FMDs (non-DC2 FMDs)
State Controller
SFF, LFF drive
trays
Dense intermix drive tray
Operating 50°F to 104°F
(10°C to 40°C)
50°F to 104°F
(10°C to 40°C)
50°F to 95°F (10°C to 35°C)
Non-operating 14°F to 122°F
(-10°C to 50°C)
14°F to 122°F
(-10°C to 50°C)
14°F to 122°F (-10°C to 50°C)
Transport, storage -22°F to 140°F
(-30°C to 60°C)
-22°F to 140°F
(-30°C to 60°C)
-22°F to 140°F (-30°C to 60°C)
Temperature
change r
ate
(°C/h)
10 or less
State Controller FMD drive trays
Operating 50°F to 104°F
(10°C to 40°C)
DKC-F710I-1R6FM or DKC-F710I-3R2FM drive is installed:
50°F to 95°F (10°C to 35°C)
Operating 50°F to 104°F
(10°C to 40°C)
DKC-F810I-1R6FN, DKC-F810I-3R2FN, or DKC-
F810I
-6R4FN drive is installed: 50°F to 104°F (10°C to
40°C)
Non-operating 14°F to 122°F
(-10°C to 50°C)
14°F to 95°F (-10°C to 35°C)
Transport, storage -22°F to 140°F
(-30°C to 60°C)
-22°F to 122°F (-30°C to 50°C)
Temperature
change rate
(°C/h)
10 or less