Item Controller
SFF, LFF, dense
intermix drive trays
(range for setup)
supports SAS 7.2k
driv
es)
RAID configuration
(unit of addition)
RAID 1 N/A 2D+2D, 4D+4D
RAID 5 N/A 3D+1P, 4D+1P, 6D+1P,
7D+1P
RAID 6 N/A 6D+2P, 12D+2P, 14D
+2P
Item Controller
FMD drive tray (range
for setup)
RAID level N/A SAS, SAS 7.2 krpm,
flash driv
es mounted:
0, 1, 5, 6, 1+0 (DBW
supports SAS 7.2k
drives)
RAID configuration
(unit of addition)
RAID 1 N/A 2D+2D, 4D+4D
RAID 5 N/A 3D+1P, 4D+1P, 6D+1P,
7D+1P
RAID 6 N/A 6D+2P, 12D+2P, 14D
+2P
Note: Although certain RAID configur
ations support redundancy in the event
of a drive failure, best practices dictate that you back up data on a regular
basis.
iSCSI specifications
Item Specification Comments
iSCSI target function Supported N/A
iSCSI target function Supported TrueCopy® only
iSCSI ports 2 per interface board
VSP Gx00 models: Maximum 32
per iSCSI system
Connection methods Direct and switch connections
Host connections 255 (maximum per iSCSI port) With Linux software initiator,
the maximum number
decreases.
114 Storage system specifications
Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide