EasyManuals Logo

Hitachi L100 Series Service Manual

Hitachi L100 Series
69 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
Table 7-1 Measuring Instruments
Item
Instruments
Type of Instrument
Remarks
Supply voltage
E1
E
L1-L2
, E
L2-L3
and E
L3-L1
Moving iron type voltmeter or
Rectifier type voltmeter
Fundamental wave
effective value
Supply current
I1
I
L1
, I
L2
and I
L3
Moving iron type ammeter Total effective value
Supply power
W1
W
11
and W
12
Electrodynamics wattmeter Total effective value
Supply power
Factor Pf1
Calculate from above measured values E1, I1 and W1
Pf
W
EI
1
3
100
1
11
=
⋅⋅
×
(%)
Output voltage
Eo
E
U-V
, E
V-W
and E
W-U
According to Fig.7-1 and Fig.7-2 Total effective value
Output current
Io
I
U
, I
V
and I
W
Moving iron type ammeter Total effective value
Output power
Wo
W
O1
and W
O2
Electrodynamics wattmeter Total effective value
Output power
factor Pf2
Calculate from above measured values Eo, Io and Wo
Pf
W
EI
O
OO
1
3
100
=
⋅⋅
×
(%)
NOTE : Use a meter indicating a fundamental wave effective value for voltage, and meters indicating
total effective values for current and power.
7-3

Other manuals for Hitachi L100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi L100 Series and is the answer not in the manual?

Hitachi L100 Series Specifications

General IconGeneral
BrandHitachi
ModelL100 Series
CategoryInverter
LanguageEnglish

Related product manuals