Page #17 background image
16
A_41 Torque boost method selection
00 Manual torque boost
01 Automatic torque boost
00
A_42 Manual torque boost value 11
A_43 Manual torque boost frequency adjust-
ment
10.0
A_44 V/f characteristic curve selection
00 V/f constant torque
01 V/f variable torque
00
A_45 V/f gain setting 100
A_51 DC braking enable
00 Disable 01 Enable
00
A_52 DC braking frequency setting 0.5
A_53 DC braking wait time 0.0
A_54 DC braking force during deceleration 0
A_55 DC braking time for deceleration 0.0
A_61 Frequency upper limit setting 0.0
A_62 Frequency lower limit setting 0.0
A_63
A_65
A_67
Jump (center) frequency setting 0.0
A_64
A_66
A_68
Jump (hysteresis) frequency width
setting
0.5
A_71 PID Enable
00 PID operation OFF
01 PID operation ON
00
A_72 PID proportional gain 1.0
A_73 PID integral time constant 1.0
A_74 PID derivative time constant 0.0
A_75 PV scale conversion 1.00
A_76 PV source setting
00 [OI] terminal (current input)
01 [O] terminal (voltage input)
00
A_81 AVR function select
00 AVR enabled 01 AVR disabled
02 AVR enabled except during decel
02 / 00 / 02
Func.
Code
Name / Description
Default
Value
–FE / –FU /
–FR
Set
Value

Other manuals for Hitachi L100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi L100 Series and is the answer not in the manual?

Hitachi L100 Series Specifications

General IconGeneral
BrandHitachi
ModelL100 Series
CategoryInverter
LanguageEnglish

Related product manuals