18
B_12 Level of electronic thermal setting Rated
current of
each inverter
B_13 Electronic thermal characteristic
00 Reduced torque 01 Const. torque
01 / 01 / 00
B_21 Overload restriction operation mode
00 Disabled
01 Enabled for accel and constant
speed
02 Enabled for constant speed only
01
B_22 Overload restriction setting Rated
current
x 1.25
B_23 Deceleration rate at overload restriction 1.0
B_31 Software lock mode selection
00 Low-level access, [SFT] blocks
edits
01 Low-level access, [SFT] blocks
edits (except F_01 and Multi-speed
parameters)
02 No access to edits
03 No access to edits except F_01 and
Multi-speed parameters
01
B_32 Reactive current setting
Note: For Japanese (–FR) versions, only
–055LFR, –055HFR, –075LFR, and
–075HFR models support this function.
58% rated
current
B_81 [FM] terminal analog meter adjustment 80
B_82 Start frequency adjustment 0.5
B_83 Carrier frequency setting 5.0 / 5.0 /
12.0
B_84 Initialization mode (parameters or trip
history)
00 Trip history clear
01 Parameter initialization
00
B_85 Country code for initialization
00 Japan version 01 Europe
version
•02US version
01 / 02 / 00
B_86 Frequency scaling conversion factor 1.0
B_87 STOP key enable
00 Enable 01 Disable
00
Func.
Code
Name / Description
Default
Value
–FE / –FU /
–FR
Set
Value

Other manuals for Hitachi L100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi L100 Series and is the answer not in the manual?

Hitachi L100 Series Specifications

General IconGeneral
BrandHitachi
ModelL100 Series
CategoryInverter
LanguageEnglish

Related product manuals