1- 14
Function Mode
Code Function name L300P Setting range
Initial data
-FE/-FU/-FR
N o t e
C070 Data command 02(operator)/03(RS485)/04(option1)/05(option2) 02
C071
Communicating
transmission speed
02(loop-back test)/03(2400bps)/04(4800bps)/
05(9600bps)/06(19200bps)
04
C072 Communication code 1. - 32. 1.
C073 Communication bit 7(7bit)/8(8bit) 7
C074 Communication parity 00(no parity name)/01(even parity)/02(odd parity) 00
C075 Communication stop bit 1(bit)/2(bit) 1
C078
Communication waiting
time
0.-1000.(ms) 0.
C081 O adjustment 0.-9999./1000-6553(10000-65530)
Setting on
forwarding
C082 OI adjustment 0.-9999./1000-6553(10000-65530)
Setting on
forwarding
C083 O2 adjustment 0.-9999./1000-6553(10000-65530)
Setting on
forwarding
C085 Thermistor adjustment 0.0 - 1000. 105.0
C086 AM offset adjustment 0.0 - 10.0(V) 0.0
C087 AMI adjustment 0. - 255. 80
C088 AMI offset adjustment 0. - 20.0( mA) 4.0
b034
RUN time/Power ON time
level
0.-9999./1000-6553(10000-65530)hr 0.
b035 Operation direction restrict 00(Reverse is valid)/01(Only forward)/02(Only reverse) 00
b036 Start reduced voltage
00(Start reduced voltage time small)
-06(Start reduced voltage time large)
06
b037 Display selection
00(all display)/01(each function display)/
02(User setting / main setting)
00
b080 AM adjustment 0. - 255. 180
b081 FM adjustment 0. - 255. 60
b082 Start frequency adjustment 0.10-9.99(Hz) 0.50
b083 Carrier frequency setting 0.5-12.0(kHz) Derating enable, <0.5-8.0kHz> 3.0
b084 Initialize mode
00(Trip history clear)/01(Data initialization)/
02(Trip history clear + data initialization)
00
b085
Country code for
initialization
00(Interior)/01(EC)/02(USA) 01/02/00
b086
Frequency scalar
conversion factor
0.1-99.9 1.0
b087 STOP key enable 00(valid)/01(invalid) 00
b088
Resume on FRS
cancellation mode
00(0Hz start)/01(Start f-equaling) 00
b090 BRD usage ratio 0.0-100.0(%) 0.0
b091 Stop mode selection 00(deceleration stop)/01(Free-run stop) 00
b092 Cooling fan control
00(Always ON)/01(ON during run, After power ON, then for 5 minutes
on stop is implied.)
00
b095 BRD selection
00(invalid)/01(valid<invalid during stop>)/
02(valid<valid during stop>)
00
b096 BRD ON level 330-380/660-760(V) 360/720
b098 Thermistor selection
00(invalid)/01(Positive temperature coefficient enable)/
02 (NTC enable)
00
b099 Thermistor error level 0. 9999. ( ohm) 3000.
C061 Thermal warning level 0. 100. ( %) 80
C091 Debug mode selection 00(No display)/01(Display) 00
C101 UP/DWN selection 00(No frequency data)/01(Keep frequency data) 00
C102 Reset selection
00(Trip cancel during ON)/01(Trip cancel during OFF)/
02(Valid only during trip<Cancel during ON>)
00
C103
Reset f frequency matching
selection
00(0Hz start)/01(Start f-equaling) 00
C121 O zero adjustment 0.-9999./1000-6553(10000-65530)
Set on
forwarding
C122 OI zero adjustment 0.-9999./1000-6553(10000-65530)
Set on
forwarding
C123 O2 zero adjustment 0.-9999./1000-6553(10000-65530)
Set on
forwarding
H003
1
st
allowable motor
selection
0.20-90.0(kW) <0.20-160(kW)>
Set on
forwarding
H203
2
nd
allowable motor
selection
0.20-90.0(kW) <0.20-160(kW)>
Set on
forwarding
H004 1
st
motor pole selection 2/4/6/8(pole) 4
H204 2
nd
motor pole selection 2/4/6/8(pole) 4
H006 1
st
stabilized factor 0. - 255. 100.
H206 2
nd
stabilized factor 0. - 255. 100.
P001
Option1 operation selection
on error
00(TRP)/01(RUN) 00
P002
Option2 operation selection
on error
00(TRP)/01(RUN) 00
P031
Digital input option input
mode selection(Acc/Dec)
00(operation)/01(option1)/02(option2) 00
P044
DeviceNet running order of
monitoring timer setting
0.00-99.99s 1.00
P045
Setting in action of
abnormal communication
00(trip)/01(trip after deceleration stop)/02(invalid)/
03(free-run)04(deceleration stop)
0.
P046
Output assemble instance
Number setting
20,21,100 21
P047
Input assemble instance
Number setting
70,71,101 71
P048
Detect of idol mode for
motion setting
00(trip)/01(trip after deceleration stop)/02(invalid)/
03(free-run)04(deceleration stop)
01
P049
Pole setting of rotation
speed
0-38(even only) 0
(Note) < > indicate the setting range of 90 to 132kW
(Note1)P044-P049 are displayed on a 0.4-75kW model.
Analog meter setting
ation