9. MAINTENANCE [How to Service the Air Compressor]
Strainer
Element
Gasket
Plug
Tighten
Loosen
Check the condensate drain
Moisture in the intake air, especially in hot and humid environments, is condensed inside the air compressor during
compression. Daily inspect intercooler/aftercooler condensate drain to verify that there is a discharge of compressed
air (with condensate) when the air compressor is loaded. Bi-annually, clean the strainer element and annually clean the
orifice for both intercooler/aftercooler.
Cleaning of strainer element
The strainers for both the intercooler and aftercooler
shall be cleaned.
Discharge the compressed air in the procedure in 9.4
󱦱.
Remove the cover of the strainer.
Remove the element, wash with water and blow air.
Remove the element from inside the strainer and
wash with water.
Replace the cleaned element in its original position
and set the O-ring or gasket, and plug properly.
Cleaning of strainer
Cleaning of orifice
Inspect and clean the orifices annually. Be sure to
stop the air compressor before inspecting and/or
cleaning the orifices.
Replacement of the strainer and solenoid
valve
Replace the solenoid valve and the strainer every 2
years (if operating 8000 hours/year) or 3 years (if
operating 4000 hours/ year) to new whole assembled
parts.
Orifice
Orifice
Cleaning of orifice
CAUTION
Verify that there is discharged air with
condensate is discharged through the drain
ports of intercooler and aftercooler every
45seconds for 45/55 kW model and every 30
seconds for 75 kW model during loading.
If compressed air is not discharged, clean
and unclog the drain port (filter & orifice).
Operating the air compressor without
draining the condensate from the
intercooler/afterooler, may rust the airend
internally and cause a major failure.
3
Condensate drain port (Intercooler/Aftercooler) (Daily check)
Clean the strainer elements (Bi-Annually) & Orifices (Annually)

Other manuals for Hitachi NEXT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi NEXT Series and is the answer not in the manual?

Hitachi NEXT Series Specifications

General IconGeneral
BrandHitachi
ModelNEXT Series
CategoryAir Compressor
LanguageEnglish

Related product manuals