34
3. OPERATION PROCEDURE [Daily Operation of Oil Mist Remover, Adjustment Procedure]
3.6 Daily Operation of Oil Mist Remover
3.6.1 When Setting 3.6.2 When Stopped
Make sure that the vacuum indicator shows a red mark.
Condensate Drain Cock
Pressure gauge (psi)
22 to 26
Make sure that the
condensate is not
collected in the
filter bowl.
If the condensate is
collected, push up
the cock to drain
the condensate.
Make sure that the vacuum
indicator does not show a
red mark.
Make sure that the pressure gauge
reads as above.
The interstage pressure of as low as -12 psi (-0.08 MPa)
during
unloading period may increase the discharge air
temperature.
IMPORTANT
3.7 Adjustment Procedure
Air Intake filter
Suction throttle valve
Locknut
Seal washer
Usually keep the bolt tightened,
but not excessively.
Adjusting Bolt
(Suction Bypass Valve)
When dust particles accumulate on the valve plate of
the suction throttle valve, the suction vacuum
pressure may drop and eventually causing the
discharge air temperature to rise.
The first steps to resolve the lower suction vacuum
pressure are as following. If the unloaded interstage
pressure drops as low as -12 psi (-0.08 MPa) or
discharge air temperature is gradually increased.
A) Clean or replace the air intake filter.
B) Clean the suction throttle valve’s valve plate.
If the air compressor cannot be shutdown to clean
these parts, turn the adjusting bolt (the suction
bypass valve) counterclockwise to open. This will
allow the air intake and increase the discharge air
pressure to be greater than -12 psi (-0.08 MPa) when
running unloaded.
Replace the consumable parts in the air intake filter
and suction throttle valve with new consumable parts
in accordance with the appropriate maintenance
schedule.(
9. Maintenance the air compressor.)
3.7.1 Adjusting the Suction Bypass Valve
(For Fixed-Speed Compressor)
The illustration below is an example of water cooler.

Other manuals for Hitachi NEXT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi NEXT Series and is the answer not in the manual?

Hitachi NEXT Series Specifications

General IconGeneral
BrandHitachi
ModelNEXT Series
CategoryAir Compressor
LanguageEnglish

Related product manuals