EasyManua.ls Logo

Hitachi PJ-TX100 - Lamp Replacement Procedure; Replacing the Projector Lamp

Hitachi PJ-TX100
65 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
32
PJ-TX100(C11H)
Wiring diagram 4 (C11H)
CNBAR
Exhaust
fan
CNPOW
Sub fan
CNSH
Internal
air sensor
External
air sensor
Panel fan
CNRM
Iris
CNME
Pass CNRM and iris leads through
fasteners (2) on side of lens shift
(to prevent contact with legs and lens
shift moving parts).
Pass panel fan, internal air sensor, and
external air sensor leads through hook
on side of intake upper (to prevent
contact with lens shift mechanism).
(1) Attach panel fan, internal air sensor, external air
sensor, and CNRM lead.
(2) Attach iris lead.
(3) Attach TSW.
(4) Connect lamp lead. Attach FEB4.
(5) Do not snag CN1.
Optical engine / exhaust duct mounting wiring
TSW
Confirm TSW marking is
“YS11A85A-D**.”
Assemble with
marking facing duct.
FEB4
Maintain clearance around duct to prevent leads snagging
when mounting optical engine / exhaust duct.
Attach FEB4 to lamp lead.
Keep close to shield
case.
ZTP1
Position CNSP lead on
optical engine as shown.
Tape down with ZTP1.
Position igniter lead on exhaust duct as
shown, and tape down (to prevent lead
from protruding into top of fan when
attaching upper case).
ZTP3

Other manuals for Hitachi PJ-TX100