11.8 Capacitors (CB1 and CB2 / CB3)
CB1 and CB2
This part is used to change the alternating current to direct current for the inverter.
Item Specifications
Model LNX2W472MSEEHE
Static electricity capacity
4700 μF
Rated voltage 450 V
Allowed temperature range -25 °C to 85 °C
Two capacitors in line are used.
CB3
This part is used to change the alternating current to direct current for fan controller.
Item Specifications
Model LNT2W272MSEAHE
Static electricity capacity
2700 μF
Rated voltage 450 V
Allowed temperature range -25 °C to 105 °C
11 Electrical checks of the