7.6.2 Motor vibrates
Motor vibrates or emits
an unusual sound
Whether the motor
parameters and motor type
are set correctly ?
If it is an inverter fault,
contact our company
Whether unusual
fluctuations occurs on the
load?
Whether unusual
fluctuations occurs when it
runs at the set frequency?
Whether the ASR and ACR
parameters are set
properly?
Whether it is vector
control?
Whether autotuning is
performed?
Set the motor type
and parameters
correctly
Perform autotuning
Set the parameter
properly
Whether the V/F
vibration parameter is
set properly?
Set the parameters
properly
Check the set
frequency
Check the load
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi S1 Series and is the answer not in the manual?

Hitachi S1 Series Specifications

General IconGeneral
Output Frequency0 - 400 Hz
Overload Capacity150% for 60 seconds
Frequency50/60 Hz
Control MethodSensorless Vector Control
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit
CommunicationRS485, Modbus RTU
Output Voltage3-Phase 200-240VAC, 3-Phase 380-480VAC (Matches Input Voltage)
Cooling MethodFan Cooled