S1 series standard inverter
-68-
Function
code
Name
Detailed parameter description
Default
value
P05.30
Corresponding setting of
lower limit of AI2
-100.0%100.0%
-100.0%
P05.31
Intermediate value 1 of AI2
P05.29P05.33
0.00V
P05.32
Corresponding setting of
intermediate value 1 of AI2
-100.0%100.0%
0.0%
P05.33
Intermediate value 2 of AI2
P05.31P05.35
0.00V
P05.34
Corresponding setting of
intermediate value 2 of AI2
-100.0%100.0%
0.0%
P05.35
Upper limit value of AI2
P05.3310.00V
10.00V
P05.36
Corresponding setting of
upper limit of AI2
-100.0%100.0%
100.0%
P05.37
Input filter time of AI2
0.000s10.000s
0.100s
P05.38
Lower limit of
AI3
-10.00VP05.39
-10.00V
P05.39
Corresponding setting of the
lower limit of AI3
-100.0%100.0%
-100.0%
P05.40
Middle value of AI3
P05.38P05.42
0.00V
P05.41
Corresponding middle
setting of AI3
-100.0%100.0%
0.0%
P05.42
Upper limit of AI3
P05.4010.00V
10.00V
P05.43
Corresponding setting of
the upper limit of AI3
-100.0%100.0%
100.0%
P05.44
AI3 input filter time
0.000s10.000s
0.100s
P05.45
Lower limit frequency of
HDI/HDIA
0.000 KHz P05.41
0.000KHz
P05.46
Corresponding setting of
lower limit frequency of
HDI/HDIA
-100.0%100.0%
0.0%
P05.47
Upper limit frequency of
HDI/HDIA
P05.39 50.000KHz
50.000KHz
P05.48
Corresponding setting of
upper limit frequency of
HDI/HDIA
-100.0%100.0%
100.0%
P05.49
HDI/HDIA frequency input
filter time
0.000s10.000s
0.030s
P05.50
Lower limit frequency of
HDIB
0.000 KHz P05.47
0.000KHz
P05.51
Corresponding setting of
lower limit frequency of HDIB
-100.0%100.0%
0.0%

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi S1 Series and is the answer not in the manual?

Hitachi S1 Series Specifications

General IconGeneral
Output Frequency0 - 400 Hz
Overload Capacity150% for 60 seconds
Frequency50/60 Hz
Control MethodSensorless Vector Control
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit
CommunicationRS485, Modbus RTU
Output Voltage3-Phase 200-240VAC, 3-Phase 380-480VAC (Matches Input Voltage)
Cooling MethodFan Cooled