Loading...
4-57
Chapter 4
For parameter configuration
[Ud-38] to [Ud-60]
Trace function
Code/Name
Range (unit)
Initial
value
Ud-38 Trace signal 6
input/output selection
00 (Input: [Ud-39])/
01 (Output: [Ud-40])
00
Ud-39 Trace signal 6 input
terminal selection
Similar to [CA-01]
001
Ud-40 Trace signal 6 output
terminal selection
Similar to [CC-01]
001
Ud-41 Trace signal 7
input/output selection
00 (Input: [Ud-42])/
01 (Output: [Ud-43])
00
Ud-42 Trace signal 7 input
terminal selection
Similar to [CA-01]
001
Ud-43 Trace signal 7 output
terminal selection
Similar to [CC-01]
001
Ud-50 Trace trigger 1
selection
00(Trip)/01(Data 0)/
02(Data 1)/03(Data 2)/
04(Data 3)/05(Data 4)/
06(Data 5)/07(Data 6)/
08(Data 7)/
09(Signal 0)/10(Signal 1)/
11(Signal 2)/12(Signal 3)/
13(Signal 4)/14(Signal 5)/
15(Signal 6)/16(Signal 7)
00
Ud-51 Trigger 1 activation
selection at trace data trigger
00(Action at rising above
the trigger level)/
01(Action at falling below
the trigger level)
00
Ud-52 Trigger 1 level
setting at trace data trigger
0 to 100(%)
0
Ud-53 Trigger 1 activation
selection at trace signal
trigger
00(Action by signal on)/
01(Action by signal off)
00
Ud-54 Trace trigger 2
selection
00(Trip)/01(Data 0)/
02(Data 1)/03(Data 2)/
04(Data 3)/05(Data 4)/
06(Data 5)/07(Data 6)/
08(Data 7)/
09(Signal 0)/10(Signal 1)/
11(Signal 2)/12(Signal 3)/
13(Signal 4)/14(Signal 5)/
15(Signal 6)/16(Signal 7)
00
Ud-55 Trigger 2 activation
selection at trace data trigger
00(Action at rising above
the trigger level)/
01(Action at falling below
the trigger level)
00
Ud-56 Trigger 2 level
setting at trace data trigger
0 to 100(%)
0
Ud-57 Trigger 2 activation
selection at trace signal
trigger
00(Action by signal on)/
01(Action by signal off)
00
Ud-58 Trigger condition
selection
00(At trace trigger 1
activation)/
01(At trace trigger 2
activation)/
02(Trigger-1 OR trigger-2
activation)/
03(Trigger-1 AND trigger-2
activation)
00
Ud-59 Trigger point setting
0 to 100(%)
0
Ud-60
Sampling time setting
01(0.2ms)/02(0.5ms)/
03(1ms)/04(2ms)/
05(5ms)/06(10ms)/
07(50ms)/08(100ms)/
09(500ms)/10(1000ms)
03
For more information, contact your supplier or local Hitachi
inverter sales office.
[UE-01] to [UE-48]
EzSQ
Code/Name
Range (unit)
Initial
value
UE-01
EzSQ execution cycle
00(1ms)/
01(2ms: SJ700/L700
compatible)
00
UE-02
EzSQ enable setting
00(Disable)/
01([PRG] terminal)/
02(Always enabled)
00
EzSQ creates a program with inverter setup software
ProdriveNext. To operate the EzSQ function, it is necessary to
download the program into the inverter.
Code/Name
Range (unit)
Initial
value
UE-10 EzSQ User parameter U(00)
0 to 65535
0
UE-11 EzSQ User parameter U(01)
0 to 65535
0
UE-12 EzSQ User parameter U(02)
0 to 65535
0
UE-13 EzSQ User parameter U(03)
0 to 65535
0
UE-14 EzSQ User parameter U(04)
0 to 65535
0
UE-15 EzSQ User parameter U(05)
0 to 65535
0
UE-16 EzSQ User parameter U(06)
0 to 65535
0
UE-17 EzSQ User parameter U(07)
0 to 65535
0
UE-18 EzSQ User parameter U(08)
0 to 65535
0
UE-19 EzSQ User parameter U(09)
0 to 65535
0
UE-20 EzSQ User parameter U(10)
0 to 65535
0
UE-21 EzSQ User parameter U(11)
0 to 65535
0
UE-22 EzSQ User parameter U(12)
0 to 65535
0
UE-23 EzSQ User parameter U(13)
0 to 65535
0
UE-24 EzSQ User parameter U(14)
0 to 65535
0
UE-25 EzSQ User parameter U(15)
0 to 65535
0
UE-26 EzSQ User parameter U(16)
0 to 65535
0
UE-27 EzSQ User parameter U(17)
0 to 65535
0
UE-28 EzSQ User parameter U(18)
0 to 65535
0
UE-29 EzSQ User parameter U(19)
0 to 65535
0
UE-30 EzSQ User parameter U(20)
0 to 65535
0
UE-31 EzSQ User parameter U(21)
0 to 65535
0
UE-32 EzSQ User parameter U(22)
0 to 65535
0
UE-33 EzSQ User parameter U(23)
0 to 65535
0
UE-34 EzSQ User parameter U(24)
0 to 65535
0
UE-35 EzSQ User parameter U(25)
0 to 65535
0
UE-36 EzSQ User parameter U(26)
0 to 65535
0
UE-37 EzSQ User parameter U(27)
0 to 65535
0
UE-38 EzSQ User parameter U(28)
0 to 65535
0
UE-39 EzSQ User parameter U(29)
0 to 65535
0
UE-40 EzSQ User parameter U(30)
0 to 65535
0
UE-41 EzSQ User parameter U(31)
0 to 65535
0
UE-42 EzSQ User parameter U(32)
0 to 65535
0
UE-43 EzSQ User parameter U(33)
0 to 65535
0
UE-44 EzSQ User parameter U(34)
0 to 65535
0
UE-45 EzSQ User parameter U(35)
0 to 65535
0
UE-46 EzSQ User parameter U(36)
0 to 65535
0
UE-47 EzSQ User parameter U(37)
0 to 65535
0
UE-48 EzSQ User parameter U(38)
0 to 65535
0

Related product manuals