4-32
Chapter 4
For parameter configuration
[Input terminal function list]
Function
code
Symbol
Function
name
Description
000
no
Not use
-
001
FW
Forward rotation
Activating (ON) only one of them
will grant forward or reverse
rotation command. [AA111]
002
RV
Reverse rotation
003
CF1
Multi-speed
selection 1
Changing the states of these
terminals, switch to the specified
frequency references.
[Ab110] to [Ab-25],
[Ab210]
004
CF2
Multi-speed
selection 2
005
CF3
Multi-speed
selection 3
006
CF4
Multi-speed
selection 4
007
SF1
Multi-speed Bit-1
008
SF2
Multi-speed Bit-2
009
SF3
Multi-speed Bit-3
010
SF4
Multi-speed Bit-4
011
SF5
Multi-speed Bit-5
012
SF6
Multi-speed Bit-6
013
SF7
Multi-speed Bit-7
014
ADD
Trigger for
frequency
addition
When [ADD] is turned ON, the
specified frequency value is added
to the current frequency
reference.[AA106]
015
SCH
G
Main/Sub speed
reference change
Main speed(OFF)/Sub-speed (ON),
to change between them use
[AA105]
016
STA
3-wire start
[STA]s ON starts the motor.
[STP]’s OFF stops the motor.
The inverter forwards operation
direction if [F/R] is (OFF), and
reverses operation direction if it is
(ON). [AA111]
017
STP
3-wire stop
018
FR
3-wire
forward/reverse
019
AHD
Analog command
holding
When the main speed input source
selection [AA101] is the analog
input 01 to 06, if AHD terminal is in
ON state, holds the Analog terminal
value.[AA101]
020
FUP
Remote control
speed-UP
function
If the frequency reference can be
set ([AHD] ON included),[FUP] ON
accelerates, and [FDN] ON
decelerates.
[UDC] returns to the saved value.
[CA-60] to [CA-66]
021
FDN
Remote control
speed-DOWN
function
022
UDC
Remote control
Speed data
clearing
023
F-OP
Force operation
[F-OP]’s ON switches command.
[CA-70],[CA-71]
024
SET
2nd-motor
control
Change between 1st-motor (OFF)
and 2nd-motor (ON).
See “4.4 Parameter naming
(Nomenclature)”
028
RS
Reset
Reset trip[bb-41], [CA-72]
029
JG
Jogging
Activates Jogging operation.
[AG-20],[AG-21]
030
DB
External dynamic
brake
Enables the DC braking operation
[AF101] to [AF109]
031
2CH
2-stage
Accel/Decel time
[2CH]’s ON changes
the Accel/Decel time. [AC115]
032
FRS
Free run stop
[FRS]’s ON allows the motor to free
run. [AA115],[bb-40]
033
EXT
External fault
[EXT]’s ON occurs error E012.
034
USP
Unattended
start protection
By turning on the power supply
while the RUN command is input,
the inverter is prevented from
starting suddenly.
Example) With [USP] = ON,
When the power supply is turned
on at the RUN command [FW] is
ON, the [E013] error is occured.
035
CS
Commercial
power supply
change
[CS] is used when switching to
commercial power. When [CS] is
turned ON, the inverter output is
cut off.
036
SFT
Soft-Lock
[SFT]’s ON prevents parameters
from being changed.[UA-16]
[Input terminal function list]
Function
code
Symbol
Function name
Description
037
BOK
Answer back
from Brake
The brake confirmation signal is
inputted for the brake control.
038
OLR
Overload
restriction
selection
Switches between Overload limit
1(OFF) and 2(ON).
[bA122] to [bA128]
039
KHC
Accumulation
input power
clearance
[KHC]’s ON clears the Accumulated
input power monitor. [UA-12]
040
OKHC
Accumulation
output power
clearance
[OKHC]’s ON clears the
Accumulated output power
monitor. [UA-14]
041
PID
Disable PID1
[PID]'s ON disables PID1 and the
PID1 set-point is used as frequency
reference. [AH-01]
042
PIDC
PID1
integration
reset
If ON, clears the integral value of
the PID1 control.
[AH-62],[AH-65]
043
PID2
Disable PID2
[PID2]'s ON disables PID2 and the
PID2 set-point is used as frequency
reference.[AJ-01]
044
PIDC2
PID2
integration
reset
If ON, clears the integral value of
the PID2 control. [AJ-14]
046
PID3
Disable PID3
[PID3]'s ON disables PID3 and the
PID3 set-point is used as frequency
reference.
[AJ-21]
046
PIDC3
PID3
integration
reset
If ON, clears the integral value of
the PID3 control. [AJ-34]
047
PID4
Disable PID4
[PID4]'s ON disables PID4 and the
PID4 set-point is used as frequency
reference.[AJ-41]
048
PIDC4
PID4
integration
reset
If ON, clears the integral value of
the PID4 control. [AJ-54]
051
SVC1
Multi set-point
selection 1
The target value can be selected by
changing the pattern of ON/OFF
states.
[AH-06]
052
SVC2
Multi set-point
selection 2
053
SVC3
Multi set-point
selection 3
054
SVC4
Multi set-point
selection 4
055
PRO
PID gain change
Switches between Gain 1(OFF) and
Gain 2(ON).
056
PIO1
PID output
switching 1
[PIO1] and [PIO2] to select which of
PID1 to PID4 will be used for PID
output.
PID1 Enable(OFF:OFF)
PID2 Enable(OFF:ON)
PID3 Enable(ON:OFF)
PID4 Enable(ON:ON)
057
PIO2
PID output
switching 2
058
SLEP
SLEEP condition
activation
In case of [SLEP] terminal selected
as sleep trigger, [SLEP]’s ON
activates the sleep function.
[AH-85]
059
WAKE
WAKE condition
activation
In case of [WAKE] terminal selected
as wake trigger, [WAKE]’s ON
activates the wake function.
[AH-93]
060
TL
Torque limit
enable
*1)
[TL]’s ON enables torque limit.
061
TRQ1
Torque limit
selection bit 1
*1)
The target value can be selected by
changing the pattern of the input
terminals ON/OFF states.
[bA111] to [bA115]
062
TRQ2
Torque limit
selection bit 2
*1)
*1) These functions are disabled when the Control mode selection
[AA121/AA221] setting is 00 to 07 (V/f control mode).

Related product manuals