For parameter configuration
[CA-01] to [CA-31]
■Parameter mode (C code)
Intelligent input terminals setting
CA-01 Input terminal [1] function
Reference
<Input
terminal
function list>
103 [PLA] Pulse
train input A is
restricted to
[CA-10],
104 [PLB] Pulse
train input B is
restricted to
[CA-11],
CA-02 Input terminal [2] function
CA-03 Input terminal [3] function
CA-04 Input terminal [4] function
CA-05 Input terminal [5] function
CA-06 Input terminal [6] function
CA-07 Input terminal [7] function
CA-08 Input terminal [8] function
CA-09 Input terminal [9] function
CA-10 Input terminal [A] function
CA-11 Input terminal [B] function
・The functions for the input terminals 1~9,A,B are
assigned in [CA-01] to [CA-09],[CA-10],[CA-11].
Input terminal NO/NC setting
CA-21 Input terminal [1] active state
00(Normally
Open: NO)/
01(Normally
Closed: NC)
CA-22 Input terminal [2] active state
CA-23 Input terminal [3] active state
CA-24 Input terminal [4] active state
CA-25 Input terminal [5] active state
CA-26 Input terminal [6] active state
CA-27 Input terminal [7] active state
CA-28 Input terminal [8] active state
CA-29 Input terminal [9] active state
CA-30 Input terminal [A] active state
CA-31 Input terminal [B] active state
・NO/NC for the Intelligent input terminals 1 to 9,A,B are
assigned in [CA-21] to [CA-29],[CA-30],[CA-31].
・However, in the case of [RS] assignment the NO/NC will
not apply, only NO will apply.
[CA-41] to [CA-55]
Input terminal chatter prevention
CA-41 Input terminal [1] response time
CA-42 Input terminal [2] response time
CA-43 Input terminal [3] response time
CA-44 Input terminal [4] response time
CA-45 Input terminal [5] response time
CA-46 Input terminal [6] response time
CA-47 Input terminal [7] response time
CA-48 Input terminal [8] response time
CA-49 Input terminal [9] response time
CA-50 Input terminal [A] response time
CA-51 Input terminal [B] response time
・Above parameters set the time to wait after the input
change has ended, and for the input to become stable
and responsive.
Time allowed in simultaneous terminal change
CA-55 Multistage input
determination time
・Sets the dead time for multistage speed and position
terminals change.