4-35
Chapter 4
For parameter configuration
[Cb-01] to [Cb-35]
Analog input adjustment
Code/Name
Range (unit)
Initial
value
Cb-01 [Ai1] Filter time
constant
1 to 500(ms)
16
Cb-03 [Ai1] Start value
0.00 to 100.00(%)
0.00
Cb-04 [Ai1] End value
0.00 to 100.00(%)
100.00
Cb-05 [Ai1] Start rate
0.0 to [Cb-06](%)
0.0
Cb-06 [Ai1] End rate
[Cb-05] to 100.0(%)
100.0
Cb-07 [Ai1] Start value
selection
00(Start value)/
01(0%)
01
Cb-11 [Ai2] Filter time
constant
1 to 500(ms)
16
Cb-13 [Ai2] Start value
0.00 to 100.00(%)
0.00
Cb-14 [Ai2] End value
0.00 to 100.00(%)
100.00
Cb-15 [Ai2] Start rate
0.0 to [Cb-16](%)
20.0
Cb-16 [Ai2] End rate
[Cb-15] to 100.0(%)
100.0
Cb-17 [Ai2] Start value
selection
00(Start value)/
01(0%)
01
Cb-21 [Ai3] Filter time
constant
1 to 500(ms)
16
Cb-22 Terminal [Ai3]
selection
00(Single)/
01(Added to Ai1/Ai2:
forward and reverse)
02(Added to Ai1/Ai2:
Forward only)
00
Cb-23 [Ai3] Start value
-100.00 to
100.00(%)
-100.00
Cb-24 [Ai3] End value
-100.00 to
100.00(%)
100.00
Cb-25 [Ai3] Start rate
-100.0 to [Cb-26]
-100.0
Cb-26 [Ai3] End rate
[Cb-25] to 100.0
100.0
Cb-30
[Ai1] Voltage/Current bias
adjustment
-100.00 to 100.00(%)
0.00
Cb-31
[Ai1] Voltage/Current gain
adjustment
0.00 to 200.00(%)
100.00
Cb-32
[Ai2] Voltage/Current bias
adjustment
-100.00 to 100.00(%)
0.00
Cb-33
[Ai2] Voltage/Current gain
adjustment
0.00 to 200.00(%)
100.00
Cb-34 [Ai3] Voltage bias
adjustment
-100.00 to 100.00(%)
0.00
Cb-35 [Ai3] Voltage gain
adjustment
0.00 to 200.00(%)
100.00
Regarding the adjustment method of the Analog input,
refer to the chapter 3.
[CA-40] to [Cb-57][CC-01] to [CC-17]
Thermistor error detection
Code/Name
Range (unit)
Initial
value
CA-40 Thermistor type
selection
00(Disable)/
01(PTC)/02(NTC)
00
Cb-41
Thermistor gain adjustment
0.0 to 1000.0
100.0
Set [Cb-40] according to the connected thermistor in TH input terminal.
When [CA-40]=01 or 02, set [bb-70] the error level. Refer to [bb-70].
In [Cb-41] thermistor gain adjustment, when the adjustment value is
raised the resistance value is lowered.
MOP volume input adjustment
Code/Name
Range (unit)
Initial value
Cb-51 MOP(VR) input filter
time constant
1 to 500
100
Cb-53 MOP(VR) start value
0.00 to 100.00(%)
0.00
Cb-54 MOP(VR) end value
0.00 to 100.00(%)
100.00
Cb-55 MOP(VR) start ratio
0.0 to [Cb-56](%)
0.0
Cb-56 MOP(VR) end ratio
[Cb-55] to
100.0(%)
100.0
Cb-57 MOP(VR) start
selection
00(Start value)/
01(0%)
01
These are the parameters when using optional operation keypad
MOP(VR).
Intelligent output terminals setting
Code/Name
Range
(unit)
Initial value
CC-01 Output terminal [11] function
Reference
<Intelligent
output
terminal
function
list>
001(RUN)
CC-02 Output terminal [12] function
002(FA1)
CC-03 Output terminal [13] function
003(FA2)
CC-04 Output terminal [14] function
007(IRDY)
CC-05 Output terminal [15] function
035(OL)
CC-06 Output terminal [16] function
*1)
000(NO)*1)
CC-07 Output terminal [AL] function
017(AL)
The functions for the output terminals 1115,AL are assigned in [CC-01]
[CC-05],[CC-07].
*1) SH1 series do not have this terminal.
Output terminal NO/NC setting
Code/Name
Range
(unit)
Initial
value
CC-11 Output terminal [11] active state
00(Normally
open: NO)/
01(Normally
closed: NC)
00
CC-12 Output terminal [12] active state
00
CC-13 Output terminal [13] active state
00
CC-14 Output terminal [14] active state
00
CC-15 Output terminal [15] active state
00
CC-16 Output terminal [16] active state
*1)
00
CC-17 Output terminal [AL] active state
01
The NO/NC setting for the Intelligent output terminals 11 to 15,AL are
assigned in [CC-11] to [CC-15], [CC-17].
*1) SH1 series do not have this terminal.