For  parameter  configuration 
[HC101] to [HC115] 
  Automatic torque boost adjustment 
HC101 Automatic torque boost 
voltage compensation gain, 1st-motor 
HC102 Automatic torque boost slip 
compensation gain, 1st-motor 
・These parameters are adjusted when the automatic 
torque boost control function is selected in [AA121]. 
For more information, please contact your supplier   
or local Hitachi inverter sales office. 
  Vector control start adjustment 
HC110 Zero speed range limit, 
1st-motor(IM-0Hz-SLV)   
HC111 Boost value at start, 
1st-motor (IM-SLV,IM-CLV) 
HC112 Boost value at start, 
1st-motor (IM-0Hz-SLV) 
・When [AA121] is sensorless vector control or 0Hz-range 
sensorless vector control, start boost is possible.   
 
  Secondary resistor compensation function 
HC113 Secondary resistance 
(R2) correction, 1st-motor 
・When the vector control (with encoder/ sensorless/0Hz) 
is being used and the temperature of the motor can be 
sensed, the inverter is capable of reducing the speed 
variations due to temperature changes. 
・If use this function, use a thermistor PB-41E from 
SHIBAURA ELECTRONICS CO., LTD. 
And also, it is necessary to set [Cb-40] to 02 (NTC). 
 
  Reverse run protection function 
HC114 Direction reversal 
protection, 1st-motor 
・This function is to prevent the change of direction of the 
output in a low frequency range for vector control such 
as (SLV/0Hz-SLV/CLV). 
 
  Torque reference value conversion method 
HC115 Torque conversion 
method selection, 1st-motor *1) 
*1) [HC115]/[HC215] are parameters added to Ver2.02 or 
later. 
•  Select the 100% reference value of the torque related 
setting parameter. (Setting 01 is the same method as 
the SJ700 series.) 
For more information, please contact your supplier   
or local Hitachi inverter sales office. 
 
 
 
 
 
 
 
[HC120] to [HC242] 
  Torque reference value conversion method 
HC120 Torque current reference filter 
time constant, 1st-motor 
HC121 Speed feedforward 
compensation gain, 1st-motor 
HC137 Flux settling level, 1st-motor *2) 
HC140 Forcing level, 1st-motor *2) 
HC141 Modulation threshold 1,   
1st-motor    *2) 
HC142 Modulation threshold 2,   
1st-motor    *2) 
・[HC120] to [HC142] are effective when the control mode is 
sensorless vector control(IM), Zero-Hz-range sensorless vector 
control (IM) or Vector control with encoder (IM). 
・[HC120] sets a filter for torque command. 
・[HC121] adjusts the compensation of feedforward control. 
・[HC137] adjusts the magnetic flux establishment level at start 
up. If this is set to a small, the waiting time until acceleration 
starts can be shortened, but the startup operation may become 
unstable. 
・[HC140] adjusts the output current level during pre-excitation. 
The basis current value is as follows depending on the control 
mode. 
08:Sensorless vector control (IM) 
09:Vector control with encoder(IM) 
[Hb116] Async. Motor 
constant I0 
10:Zero-Hz-range sensorless vector 
control 
[HC110] Zero speed range 
limit (IM -0Hz-SLV) 
・[HC141]/[HC142] adjust the upper limit of the inverter output 
voltage level. By increasing these parameters the output 
current may be reduced, and the operation may become 
unstable. 
  Be sure to set the same value for [HC141] and [HC142]. 
                             
  2nd motor When Intelligent Input terminal 024[SET] is enabled. 
HC201 Automatic torque boost voltage 
compensation gain, 2nd-motor 
HC202 Automatic torque boost slip 
compensation gain, 2nd-motor 
HC210 Zero speed range limit, 
2nd-motor(IM-0Hz-SLV) 
HC211 Boost value at start, 
2nd-motor(IM-SLV,IM-CLV) 
HC212 Boost value at start, 
2nd-motor(IM-0Hz-SLV) 
HC213 Secondary resistor (R2) compensation 
enable, 2nd-motor 
HC214 Direction reversal protection, 
2nd-motor 
HC215 Torque conversion method selection, 
2nd-motor 
HC220 Torque current reference filter time 
constant, 2nd-motor 
HC221 Speed feedforward compensation gain, 
2nd-motor 
HC237 Flux settling level, 2nd-motor    *2) 
HC240 Forcing level, 2nd-motor *2) 
HC242 Modulation threshold 2, 2nd-motor *2) 
*2)[HC137]/[HC237],[HC140]/[HC240],[HC141]/[HC241], 
[HC142]/[HC242] are parameters added to Ver2.03 or later.