For parameter configuration
[Hd202] to [Hd237]
2nd motor When Intelligent Input terminal 024[SET] is enabled.
Perm. Magnet Sync. Motor (SM/PMM)
Hd202
Sync. Motor capacity setting, 2nd-motor
Hd203
Sync. Motor number of poles setting,
2nd-motor
Hd204 Sync. Base frequency setting,
2nd-motor
Hd205 Sync. Maximum frequency setting,
2nd-motor
Hd206 Sync. Motor rated voltage,
2nd-motor
Hd208 Sync. Motor rated current,
2nd-motor
Hd210 Sync. Motor constant R,
2nd-motor
Hd212 Sync. Motor constant Ld,
2nd-motor
Hd214 Sync. Motor constant Lq,
2nd-motor
Hd216 Sync. Motor constant Ke,
2nd-motor
Hd218 Sync. Motor constant J,
2nd-motor
2nd motor When Intelligent Input terminal 024[SET] is enabled.
Hd230 Minimum frequency adjustment for
Sync.M, 2nd-motor
Hd231 No-Load current for Sync.M,
2nd-motor
Hd232 Starting method for Sync.M,
2nd-motor
Hd233 IMPE 0V wait number for Sync.M,
2nd-motor
Hd234 IMPE detect wait number for Sync.M,
2nd-motor
Hd235 IMPE detect number for Sync.M,
2nd-motor
Hd236 IMPE voltage gain for Sync.M,
2nd-motor
Hd237 IMPE Mg-pole position offset,
2nd-motor
[oA-10] to [oA-33][ob-01] to [ob-04]
■Parameter mode (o code)
・”o” parameters are displayed by the [UA-22] = 01. This
configuration is not necessary except when option is used.
・The implementation of the following parameters might differ
depending on the type of option being used.
For more information, please contact your supplier or
local Hitachi inverter sales office.
Optional cassette error operation
oA-10 Operation selection at
an option error (SLOT-1)
00(Error)/
01((Ignore error
(keep running))
oA-11 Communication
Watch Dog Timer (SLOT-1)
oA-12 Action selection at a
communication error (SLOT-1)
00(Error)/
01(Trip after Deceleration
stop)/02(Ignore)/
03(Free run stop)/
04(Deceleration stop)
oA-13 RUN command
selection at start up (SLOT-1)
oA-20 Operation selection at
an option error (SLOT-2)
00(Error)/
01((Ignore error
(keep running))
oA-21 Communication
Watch Dog Timer (SLOT-2)
oA-22 Action selection at a
communication error (SLOT-2)
00(Error)/
01(Trip after Deceleration
stop)/
02(Ignore)/
03(Free run stop)/
04(Deceleration stop)
oA-23 RUN command
selection at start up (SLOT-2)
oA-30 Operation selection at
an option error (SLOT-3)
00(Error)/
01((Ignore error
(keep running))
oA-31 Communication
Watch Dog Timer (SLOT-3)
oA-32 Action selection at a
communication error (SLOT-3)
00(Error)/
01(Trip after Deceleration
stop)/02(Ignore)/
03(Free run stop)/
04(Deceleration stop)
oA-33 RUN command
selection at start up (SLOT-3)
・In P1-CCL CC-Link communication option, there are no
dedicated parameters other than the above parameters.
For more information, please contact your supplier or
local Hitachi inverter sales office.
P1-FB Encoder Feedback Option setting
ob-01 Encoder constant
setting (option)
ob-02 Encoder phase
sequence selection (option)
00(Phase-A Lead)/
01(Phase-B Lead)
ob-03 Motor gear ratio
numerator (option)
ob-04 Motor gear ratio
denominator (option)
・Above parameters set the main encoder input and the motor
gear ratio involved in the encoder feedback for the P1-FB.