1.2 Check Inverter parameter and motor specification.
[1] Inverter specifications.
(1) Inverter specifications (Monitor mode)
Display Function name Category Screen display Initial Remarks
order Code display EU US JPN
1 Output frequency monitor Monitor d01 - - -
2 Output current monitor Monitor d02 - - -
3 Running direction monitor Monitor d03 - - -
4 Feedback data of PID
control monitor
Monitor d04 - - -
5 Intelligent input terminal
condition monitor
Monitor d05 - - -
6 Intelligent output terminal
condition monitor
Monitor d06 - - -
7 Output frequency
converted value monitor
Monitor d07 - - -
8 Trip monitor Monitor d08 - - -
9 Trip history monitor Monitor d09 - - -
(2) Inverter specifications (Basic function mode)
Display Function name Category Screen display Initial Remarks
Order Code display EU US JPN
1 Output frequency setting Set F01 0.0 0.0 0.0
2 Acceleration time 1 Set F02 10 10 10
- Acceleration time 1
(2
nd
setting)
Set F202 10 10 10
3 Deceleration time 1 Set F03 10 10 10
- Deceleration time 1
(2
nd
setting)
Set F203 10 10 10
4 Running direction setting Set F04 00 00 00
5 Extended function
A group setting
Set A--
6 Extended function
B group setting
Set B--
7 Extended function
C group setting
Set C--
8 Extended function
H group setting
Set H--
Note; “-“ means hidden display ;depends on 2nd setting selection.
(3) Inverter specifications (Extended function mode : A group)
Displa
y
Function name Category Screen display Initial Remarks
Order Code display EU US JPN
1 Frequency destination Set
A01
01 01 00
2 Running command
destination
Set
A02
01 01 02
3 Base frequency Set
A03
50 60 60
- Base frequency(2
nd
setting) Set
A203
50 60 60
4 Maximum frequency Set
A04
50 60 60
- Maximum frequency(2
nd
setting)
Set
A204
50 60 60
5 External freq. setting start Set
A11
000
6 External freq. setting end Set
A12
000
7 External freq. setting start
rate
Set
A13
000
8 External freq. setting end
rate
Set
A14
100 100 100
9 External freq. start pattern Set
A15
01 01 01
10 Time constant of the filter
of analog input
Set
A16
888
1-2