33
P018 Home search completion delay time setting 0.00
P019 Electronic gear set position selection
00 Position feedback side
01 Position command side
00
P020 Electronic gear ratio numerator setting 1.
P021 Electronic gear ratio denominator setting 1.
P022 Feed-forward gain setting 0.00
P023 Position loop gain setting 0.50
P025 Temp. compensation thermistor enable
00 Disable 01 Enable
00
P026 Over-speed error detection level setting 135.0
P027 Speed deviation error detection level setting 7.50
P031 Accel/decel time input selection
•00Inverter
01 Expansion card #1
02 Expansion card #2
00
P032 Positioning command input selection
•00Inverter
01 Expansion card #1
02 Expansion card #2
00
P044 DeviceNet comm watchdog timer 1.00
P045 Inverter action on DeviceNet comm error
•00Trip
01 Decelerate and trip
02 Hold last speed
03 Free run stop
04 Decelerate and stop
01
P046 DeviceNet polled I/O: Output instance number 21
P047 DeviceNet polled I/O: Input instance number 71
P048 Inverter action on DeviceNet idle mode
•00Trip
01 Decelerate and trip
02 Hold last speed
03 Free run stop
04 Decelerate and stop
01
P049 DeviceNet motor poles setting for RPM 0