38
Analog Output Function Listing
The following table shows all eight functions available for assignment to
the three analog output terminals:
• Terminal [FM], option set by C027
• Terminal [AM], option set by C028
• Terminal [AMI], option set by C029
Programming Error Codes
The SJ300 inverter operator keypad displays a special code (begins with
the character) to indicate a programming error. Programming errors
exist when one parameter conflicts with the meaningful range permitted
by related parameter(s). Note that particular real-time frequency (speed)
input levels can cause a conflict in some situations. After a conflict exists,
the error code will appear on the display, or you can view it later with
D090 in Monitor Mode. Also, the PGM LED on the display will flash
ON/OFF when programming. These indications are automatically cleared
when the parameter is corrected to the allowed range.
Option
Code
Function
Name
Description
Corresponding
Signal Range
00 Output
frequency
Actual motor speed,
represented by PWM
signal
0 to max. frequency in Hz
01 Output current Motor current (% of
maximum rated output
current), represented by
PWM signal
0 to 200%
02 Output torque Rated output torque 0 to 200%
03 Digital output
frequency
Output frequency (avail-
able only at [FM] output)
0 to max. frequency in Hz
04 Output voltage Rated output voltage to
motor
0 to 100%
05 Input power Rated input power 0 to 200%
06 Electronic
thermal
overload
Percentage of electronic
overload attained
0 to 100%
07 LAD
frequency
Internal ramp generator
frequency
0 to max. frequency in Hz