Item Specification
(bytes)
Maximum number of hosts via FC switch 255
Maximum number of hosts via network
switch
255
Battery life
Storage system intake temperature CBL
Up to 75.2º F (24º C) 5 years
Up to 86º F (30º C) 5 years
Up to 93.2º (34º C) 4 years
Up to 104º (40º C) 3 years
RAID specications
Item Specification
RAID level
1
Flash drive mounted: 1/5/6
RAID conguration RAID1: 2D+2D, 4D+4D
RAID5: 3D+1P, 4D+1P, 6D+1P, 7D+1P
RAID6: 6D+2P, 12D+2P, 14D+2P
Maximum number of parity groups 288
Maximum volume size 3 TB (when using the LDEVs of other
Storage Systems: 4TB)
Maximum volumes/host groups and iSCSI
targets
2048
Maximum volumes/parity groups 2048
Note:
1. A storage system congured with RAID6, RAID 5, or RAID 1 provides redundancy
and enhances data reliability. However, there is still a possibility of losing data
caused by unforeseeable hardware or software failure. Users should always follow
recommended best practices and back up all data.
VSP F700 mechanical specications
Appendix B: System specications
Hitachi Virtual Storage Platform F700 Hardware Reference Guide 51

Table of Contents

Other manuals for Hitachi Virtual Storage Platform F350

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi Virtual Storage Platform F350 and is the answer not in the manual?

Hitachi Virtual Storage Platform F350 Specifications

General IconGeneral
BrandHitachi
ModelVirtual Storage Platform F350
CategoryStorage
LanguageEnglish

Related product manuals