Item Description
3. Value shown is the maximum value.
Host interface specications
The following table lists the specications of the host interfaces available for the VSP
G130 controllers.
Item Specification
Interface type 16 Gbps FC (Optical)
Data transfer speed
(Max. speed for transfer to host)
400 Mbps (FC)
800 Mbps (FC)
1600 Mbps (FC)
Number of ports per controller 16 Gbps FC (Optical): 2
Number of ports per system 4
Battery life specications
Storage system intake temperature CBSL
Up to 75.2º F (24º C) 5 years
Up to 86º F (30º C) 4 years
Up to 93.2º (34º C) 3 years
Up to 104º (40º C) 2 years
CBSL component LEDs
The following table describes the denitions of the CBSL controller front panel bezel
LEDs.
Controller chassis with large form-factor drive bays (CBSL)
Chapter 2: Hardware components and specications
Hitachi Virtual Storage Platform G130 Hardware Reference Guide 28