Operation name Condition
Reconnect external
paths
Ports of the specied external paths and all the external
volumes connecting with those e
xternal paths must be
assigned to the Storage Administrator group permitted to
manage them.
When you specify By Ports, all the external paths connecting
with the specied ports and all the external volumes
connecting with the external paths must be assigned to the
Storage Administrator group permitted to manage them.
When you specify By External WWNs, all the ports of the
external paths connecting to the specied external WWN
and all the external volumes connecting with those external
paths must be assigned to the Storage Administrator group
permitted to manage them.
Edit external WWNs All the ports of the external paths connecting to the
specied external WWN and all the external volumes
connecting with the external paths must be assigned to the
Storage Administrator group permitted to manage them.
Edit external path
conguration
Ports of all the external paths composing the specied path
group and all the external volumes that belong to the path
group must be assigned to the Storage Administrator group
permitted to manage them.
Access requirements for Virtual LUN
The following table species the resource access requirements for Virtual LUN
operations.
Operation name Condition
Create LDEVs When you specify a parity group and open the Cr
eate
LDEVs window, the parity group must be assigned to the
Storage Administrator group permitted to manage them.
When you create an internal or external volumes parity
groups where the LDEV belongs and ID of the new LDEV
must be assigned to the Storage Administrator group
permitted to manage them.
Delete LDEVs When deleting an internal or external volume, the deleted
LDEV and parity groups where the LDEV belongs must be
assigned to the Storage Administrator group permitted to
manage them.
Edit LDEVs The specied LDEV must be assigned to the Storage
Administrator group permitted to manage them.