Item Description
DKC0 CL1 Temperature
maximum value
DKC0: Maximum temperature of CL1 (°C)
DKC0 CL1 Temperature
minimum value
DKC0: Minimum temperature of CL1 (°C)
DKC0 CL2 Temperature
average
DKC0: Average temperature of CL2 (°C)
DKC0 CL2 Temperature
maximum value
DKC0: Maximum temperature of CL2 (°C)
DKC0 CL2 Temperature
minimum value
DKC0: Minimum temperature of CL2 (°C)
FcSpNameInfo.csv
This CSV file contains information about Fibre Channel Security Protocols
(FCSPs). A record is created for each initiator (host).
For details of port setting, see the Provisioning Guide. Information about the
NAS module is not displayed in this CSV file.
Table 31 FcSpNameInfo.csv file (Title: <<FC-SP Name Information>>)
Item
Content
Port Port name
Host Group Host group name
Target Username WWN information about the storage system required for authentication (16-digit
hexadecimal number)
Authentication of Group Information about whether to perform authentication or not
Enabled
Disabled
Initiator Username WWN information about the host required for authentication (16-digit hexadecimal
number)
Protocol Protocol used for authentication ("CHAP" or blank)
FcSpPortInfo.csv
This CSV file contains information about ports related to Fibre Channel
Security Protocols (FCSPs). A record is created for each port.
For details of port setting, see the Provisioning Guide. Information about the
NAS module is not displayed in this CSV file.
Table 32 FcSpPortInfo.csv file (Title: <<FC-SP Port Information>>)
Item
Content
Port Port name