Loading...
Item Description
iSCSI:
10iSCSI2o (CHB)
10iSCSI2c (CHB)
NAS module:
NAS module (CHB)
Resource Group ID (Host
Group)
Resource group ID of a host group (0 to 1,023, decimal)
Resource Group Name (Host
Group)
Resource group name of a host group
T10 PI Mode Indicates whether the T10 PI mode can be applied to the port for which the LU path is
defined.
Enabled
Disabled
Blank if "Package Type" is not 16FC2 (CHB) or 32FC4R (CHB).
T10 PI Information about the T10 PI attribute which is set for the LDEV number of the LU
path definition.
Enabled
Disabled
Blank if LDEV# is blank
Asymmetric Access State
Asymmetric access status (output only for an open system CHA that is Fibre or FCoE)
Indicates the asymmetric access status:
Active/Optimized: Prioritized
Active/Non-Optimized: Lower priority
Blank if "Package Type" is iSCSI
LunPortInfo.csv
This CSV file contains information about LU path definition. A record is
created for each port.
For details of LU path definition, see the Provisioning Guide.
Table 44 LunPortInfo.csv file (Title: <<LUN Port Information>>)
Item
Content
Port Port name.
Security Switch The setting status of the security switch:
On
Off
Blank if "Package Type" is NAS module
Port Address Port address (2-digit hexadecimal number)
Blank if "Package Type" is iSCSI or NAS module
Loop ID Port address (0 - 125, decimal)
Blank if "Package Type" is iSCSI or NAS module
Fabric One of the Fibre topology settings indicating the setting status of the Fabric switch:
On
Off
Examples of storage configuration reports 337
System Administrator Guide for VSP Gx00 models and VSP Fx00 models

Table of Contents