Item Content
Time out(Sec) Time interval (in seconds) before retrying authentication in case of failure in
authentication
Refusal Intvl.(Min) Time interval (in minutes) before starting next authentication in case of failure in
authentication for the number of times displayed by "Refusal Freq(Counts)"
Refusal Freq.(Counts) Number of times of authentication allowable for connection to a port
Switch Port Username WWN information about the Fabric switch required for authentication (16-digit
hexadecimal number)
Mode Mode of authentication between ports and FC switches
Bidirectional
Unidirectional
Authentication of Fabric
Switch
Information about whether to perform authentication of the FC switch identified by
"Switch Port Username"
Enabled
Disabled
HduInfo.csv
This CSV file contains information about hard drive boxes (DB). A record is
created for each drive box.
Table 33 DBInfo.csv file (Title: <<DB Information>>)
Item
Description
DB Location DB location name
DB Status Information about whether this DB is installed
Installed
Not installed
Slot Size Slot size (inches)
2.5
3.5
Blank for DBF (FMC and FMD).
DB Type DB type
DBS (DB for 2.5-inch drives)
DBL (DB for 3.5-inch drives)
DB60 (dense drive box for 3.5-inch drives)
DBF (DB for FMC and FMD, 2PORT)
IscsiHostInfo.csv
This CSV file contains information about iSCSI Initiator (Host) set to the
channel board port. A record is created for each iSCSI Host (Initiator) target.
Information about the NAS module is not displayed in this CSV file.
328 Examples of storage configuration reports
System Administrator Guide for VSP Gx00 models and VSP Fx00 models

Table of Contents

Related product manuals