Do you have a question about the Hitachi WL200 Series and is the answer not in the manual?
Series | WL200 |
---|---|
Output Frequency | 0 to 400 Hz |
Overload Capacity | 150% for 60 seconds |
Protection Functions | Overcurrent, Overvoltage, Undervoltage, Overheat, Short circuit |
Cooling Method | Fan cooled |
Communication Interface | RS-485 (Modbus RTU) |
Operating Temperature | -10 to +50°C (14 to 122°F) |
Humidity | 5 to 95% RH (non-condensing) |
Altitude | Up to 1000m (Above sea level) |
Input Voltage | 3-Phase 200 to 240 VAC, 3-Phase 380 to 480 VAC |
Output Voltage | 3-Phase 200 to 240 VAC, 3-Phase 380 to 480 VAC (depending on input voltage) |
Verifies product contents, condition, and packaging upon purchase.
Details required information for inquiries and warranty coverage.
Describes the WJ-PN as a PROFINET interface option for WJ200/WL200.
Explains compatibility based on inverter product version.
Lists limitations such as Modbus communication being unusable.
Details external features including LEDs and connectors.
Summarizes the function of LEDs and connectors.
Outlines necessary checks before installing the WJ-PN option.
Provides step-by-step instructions for attaching the WJ-PN.
Details the RJ-45 connector type and pin assignments.
Recommends Ethernet cable specifications for optimal performance.
Illustrates example PROFINET system configurations.
Instructs on installing ferrite cores on LAN cables.
Advises on safe operation and interlocks for adjustable speed drives.
Guides through essential inverter and WJ-PN parameter settings.
Explains how to control the inverter using frequency commands via PROFINET.
Explains the necessity of installing the GSDML file for PROFINET communication.
Details crucial parameter settings required for WJ-PN operation.
Shows the association map for selecting frequency sources.
Covers PROFINET, LLDP, SNMP, and PROFIdrive specifications.
Explains PROFIdrive state machines, control, and status words.
Details NSOLL_A/NIST_A, telegrams, and parameter access methods.
Covers PNU mapping, faults, and warnings for troubleshooting.
Explains indicator lighting statuses and their meanings.
Lists inverter error codes and their possible causes and remedies.
Provides hints on parameter combinations affecting inverter behavior.
Offers hints on power-on order, replacement, and network analysis.
Lists information required for technical support.
Provides detailed technical specifications for the WJ-PN.
Shows physical dimensions and appearance of the WJ-PN.
An overview of the PROFINET object list structure.
Lists parameters for monitoring in group 'd'.
Lists parameters for function mode group 'A'.
Lists parameters for function mode group 'C'.
Lists parameters for function mode group 'H'.
Details the PROFIdrive parameter allocation.