Draining operation for YUTAKI M
YUTAKI M has no drain port factory supplied. It is highly recommended to install a drain port valve attached to the water outlet of the
YUTAKI M unit in order to ease the operation of draining. When the drain port is installed the draining procedure for the YUTAKI M
follows the next steps:
1 Switch OFF the main power of the unit.
2 Close the shut-off valve installed at the water inlet connection (eld supplied).
3 Connect a pipe or a drain hose to the drain port (eld supplied) placed in the water outlet pipe of the unit.
4 Open manually the drain port of the shut-off valve (eld supplied), and collect the water into a bucket (or to a sewage system)
5 Once all the water has been drained, and all maintenance operations have been nished, close again the drain port and open
again the valve of the water inlet pipe to restart the normal operation of the unit.