3.3.4 Monobloc system - YUTAKI M
Model RASM-3VNE RASM-4VNE RASM-5VNE RASM-6VNE
Power supply - 1~ 230V 50Hz
Noise level (sound pressure) (*1)(*2) dB(A)
Noise level (sound power)
(*1) dB(A)
64 64 65 67
(*2) dB(A)
61 63 64 65
Cabinet
Material - Precoated galvanised steel
Colour - Natural grey (1.0Y 8.5/0.5)
Unit dimensions
Height mm 800 1380
Width mm 1252 1252
Depth mm 370 370
Packaging dimensions
Height mm 935 1515
Width mm 1312
Depth mm 460
Packaging volume 0.56 0.91
Packaging materials - Paper + Wood + Plastic
Net weight kg 105 125 130 134
Gross weight kg 115 135 140 144
Space heating pipes
connection
Connection type - Screwed connection
Shut-off valves mm (in.)
G 1” (male) -
G 1” (male)
G 1-1/4” (male) - G 1-1/4” (male)
Inlet pipe diameter mm (in.) G 1” (female) G 1-1/4” (female)
Outlet pipe diameter mm (in.) G 1” (female) G 1-1/4” (female)
Working range (Heating)
Outdoor ambient temperature ºC (DB) -25~25
Outlet water temperature ºC 20~55 20~60
Working range (Cooling)
Outdoor ambient temperature ºC (DB) 10~46
Outlet water temperature ºC 5~22
Working range (DHW)
Outdoor ambient temperature ºC (DB) -25~35
Tank water temperature ºC 30~75
Refrigerant - R410A
Refrigerant charge kg 2.4 2.8 3.1 3.1
Compressor type - Scroll DC Inverter driven
Blank data: To be informed later.
GENERAL DATA
PMML0335A rev.1 - 04/2016
48

Table of Contents

Other manuals for Hitachi YUTAKI RWM-2R1E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi YUTAKI RWM-2R1E and is the answer not in the manual?

Hitachi YUTAKI RWM-2R1E Specifications

General IconGeneral
BrandHitachi
ModelYUTAKI RWM-2R1E
CategoryAir Conditioner
LanguageEnglish

Related product manuals