EasyManua.ls Logo

Hitachi YUTAKI S80 Series - Page 29

Hitachi YUTAKI S80 Series
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH
YUTAKI S COMBI
Outdoor unit model
RAS-2
WHVNP
RAS-2.5
WHVNP
RAS-3
WHVNP
RAS-4
WH(V)NPE
RAS-5
WH(V)NPE
RAS-6
WH(V)NPE
Indoor unit model
RWD-2.0
NW(S)E-
(200/260)
S(-K)
RWD-2.5
NW(S)E-
(200/260)
S(-K)
RWD-3.0
NW(S)E-
(200/260)
S(-K)
RWD-4.0
NW(S)E-
(200/260)
S(-K)
RWD-5.0
NW(S)E-
(200/260)
S(-K)
RWD-6.0
NW(S)E-
(200/260)
S(-K)
OAT
(DB/WB)
WIT / WOT - Unit Heating operation
7 / 6 ºC
30 / 35 ºC
CAP (Nom./Max.) kW 4.3/7.0 6.0/9.0 7.5/11.0 11.0/15.2 14.0/16.7 16.0/17.8
COP (Nom.) - 5.25 4.80 4.55 5.00 4.71 4.57
40 / 45 ºC
CAP (Nom./Max.) kW 4.3/6.2 6.0/9.0 7.5/10.0 11.0/14.1 14.0/15.7 16.0/17.3
COP (Nom.) - 3.90 3.59 3.50 3.98 3.61 3.40
47 / 55 ºC
CAP (Nom./Max.) kW 4.3/6.0 6.0/8.0 7.5/9.2 11.0/13.5 14.0/15.2 16.0/17.0
COP (Nom.) - 3.0 2.89 2.57 3.00 2.80 2.50
2 / 1 ºC 30 / 35 ºC
CAP (Nom./Max.) kW 3.5/5.5 4.5/7.0 5.5/8.9 9.5/12.8 10.5/13.9 11.1/15.0
COP (Nom.) - 4.10 3.65 3.53 3.61 3.55 3.41
-7 / -8 ºC
30 / 35 ºC
CAP (Nom./Max.) kW 4.3/4.7 5.3/5.7 5.8/6.7 9.7/10.6 11.5/12.0 12.0/13.0
COP (Nom.) - 2.85 2.60 2.57 2.74 2.65 2.57
40 / 45 ºC
CAP (Nom./Max.) kW 4.3/4.6 5.0/5.5 6.0/6.4 10.0/10.0 11.0/11.6 11.5/12.5
COP (Nom.) - 2.45 2.25 2.25 2.45 2.25 2.15
47 / 55 ºC
CAP (Nom./Max.) kW 4.0/4.2 4.6/5.0 5.0/5.5 8.7/9.7 9.7/11.2 10.5/12.0
COP (Nom.) - 1.93 1.82 1.60 1.78 1.85 1.75
OAT
(DB/WB)
WIT / WOT - Unit
Cooling operation
(Using cooling kit accessory)
35 / -- ºC
12 / 7 ºC
CAP (Nom.) kW 3.8/4.9 5.0/5.8 6.0/7.0 7.2/11.8 9.5/12.6 10.5/13.5
EER (Nom.) - 3.12 3.15 2.75 3.30 3.22 2.82
23 / 18 ºC
CAP (Nom.) kW 4.1/6.1 5.5/7.4 6.0/8.5 10.4/15.0 12.9/16.0 13.5/17.5
EER (Nom.) - 3.81 3.81 3.81 4.50 4.02 3.81
GENERAL DATA
PMML0335A rev.1 - 04/2016
17

Table of Contents

Other manuals for Hitachi YUTAKI S80 Series

Related product manuals