EasyManua.ls Logo

Hitachi YUTAKI S80 Series - Page 32

Hitachi YUTAKI S80 Series
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RAS-(4-6)WHVNPE + RWM-(4.0-6.0)NE
Model
Outdoor
unit
RAS-4WHVNPE RAS-5WHVNPE RAS-6WHVNPE
Indoor unit RWM-4.0NE RWM-5.0NE RWM-6.0NE
Water outlet temperature 35ºC 55ºC 35ºC 55ºC 35ºC 55ºC
Product
description
Air to water heat pump - Yes
Heat pump combination heater - No
Low temperature heat pump - No
Complementary heater - Yes
Design capacity (P
DESIGN
) kW 11.0 10.0 14.0 12.0 16.0 14.0
Nominal energy efciency (η
S
) % 187 (189) 136 (137) 175 (176) 133 (134) 153 (153) 125 (126)
Nominal energy class - A+++ A++ A+++ A++ A++ A++
Data for Packaged Fiche:
Energy efciency with OTC control (η
S
) (*) % 189 (191) 138 (139) 177 (178) 135 (136) 155 (155) 127 (128)
Energy class with OTC control - A+++ A++ A+++ A++ A++ A++
Energy efciency with thermostats/sensors (η
S
) (*) % 191 (193) 140 (141) 179 (180) 137 (138) 157 (157) 129 (130)
Energy class with thermostats - A+++ A++ A+++ A++ A++ A++
Supplementary capacity (P
SUP
) kW 0.5 1.2 1.9 1.5 1.9 2.3
Type of energy used - Electricity
Declared capacity (Pdh) and coefcient of performance (COP
d
) at partial load under the following outdoor temperatures:
Outdoor temperature (Tj) = -7ºC
Pdh kW 9.60 8.60 12.00 10.25 13.80 11.20
COP
d
- 2.74 1.80 2.55 1.70 2.40 1.60
Outdoor temperature (Tj) = +2ºC
Pdh kW 5.84 5.23 7.30 6.24 8.40 6.82
COP
d
- 5.20 3.60 4.70 3.60 3.90 3.35
Outdoor temperature (Tj) = +7ºC
Pdh kW 3.76 3.52 4.70 4.01 5.40 4.38
COP
d
- 5.80 4.80 5.70 4.60 5.00 4.35
Outdoor temperature (Tj) = +12ºC
Pdh kW 3.70 3.60 3.50 3.50 3.50 3.60
COP
d
- 6.40 5.80 6.00 5.50 6.00 5.50
Outdoor temperature (Tj) = Bivalent
temperature (T
biv
)
Pdh kW 9.60 8.60 12.00 10.25 13.80 11.20
COP
d
- 2.74 1.80 2.55 1.70 2.40 1.60
Outdoor temperature (Tj) = Limit operation
temperature (TOL)
Pdh kW 10.50 8.80 12.10 10.50 14.10 11.70
COP
d
- 2.65 1.90 2.50 1.70 2.30 1.55
Bivalent temperature (T
biv
) ºC -7 -7 -7 -7 -7 -7
Limit operation temperature (TOL) ºC
-10 -10 -10 -10 -10 -10
Water limit operation temperature (WTOL) ºC 55 55 55 55 55 55
Degradation coefcient (Cdh) - 0.9 0.9 0.9 0.9 0.9 0.9
Annual energy consumption (Q
HE
) kW·h 4714 (4666) 5786 (5738) 6313 (6265) 7042 (6994) 8287 (8239) 8170 (8122)
GENERAL DATA
PMML0335A rev.1 - 04/2016
20

Table of Contents

Other manuals for Hitachi YUTAKI S80 Series

Related product manuals