EasyManua.ls Logo

Hitachi YUTAKI S80 Series - Page 56

Hitachi YUTAKI S80 Series
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Model
RWD-4.0NWE-
(200/260)S-K
RWD-5.0NWE-
(200/260)S-K
RWD-6.0NWE-
(200/260)S-K
Power supply - 1~ 230V 50Hz / 3N~ 400V 50Hz
Noise level (sound power) dB(A) 39 39 39
Cabinet
Material - Precoated galvanised steel
Colour - Pure white (RAL 9010)
Unit dimensions
Height (with connections) mm 1750 (1816) (*3)
Width mm 600
Depth mm 733
Packaging dimensions
Height mm 1950
Width mm 651
Depth mm 770
Packaging volume 0.98
Packaging materials - Wood - Carton - Plastic
Net weight
Tank model: 200 L
kg
124 126
Tank model: 260 L 139 141
Gross weight
Tank model: 200 L
kg
135 137
Tank model: 260 L 150 152
Refrigerant pipes
connection
Connection type - Flare nut connection
Liquid pipe diameter mm (in.) Ø9.52 (3/8”)
Gas pipe diameter mm (in.) Ø15.88 (5/8”)
Space heating pipes
connection
Connection type - Screwed connection
Shut-off valves mm (in.) G 1-1/4” (male) - G 1-1/4” (male)
Inlet pipe diameter mm (in.) G 1-1/4” (female)
Outlet pipe diameter mm (in.) G 1-1/4” (female)
DHW pipes
connection
Connection type - Screwed connection
Inlet pipe diameter mm (in.) G 3/4” (female)
Outlet pipe diameter mm (in.) G 3/4” (female)
Working range
(Heating)
Outdoor ambient temperature ºC (DB) -25~25
Outlet water temperature ºC 20~60
Working range
(Cooling)
Outdoor ambient temperature ºC (DB) 10~46
Outlet water temperature ºC 5~22
Working range (DHW)
Outdoor ambient temperature ºC (DB) -25~35
Tank water temperature ºC 30~75
GENERAL DATA
PMML0335A rev.1 - 04/2016