Loading...
Model Power supply Operation mode Z
max
(Ω)
RWM-(8.0/10.0)NE(-W) 3N~ 400V 50Hz
Without electric heater -
With electric heater -
With DHW tank heater -
With electric and DHW tank heaters 0.45
? NOTE
The data corresponding to DHW tank heater is calculated in combination with the domestic hot water tank accessory “DHWT-(200/300)S-3.0H2E”.
YUTAKI S COMBI
Model Power supply Operation mode Z
max
(Ω)
RWD-(2.0-3.0)
NRW(S)E-(200/260)(-W)
(-W)
1~ 230V 50Hz
Without electric heaters -
With electric heater -
With DHW tank heater
-
With electric and DHW tank heaters 0.28
RWD-(4.0-6.0)
NW(S)E-(200/260)S
1~ 230V 50Hz
Without electric heaters -
With electric heater 0.26
With DHW tank heater -
With electric and DHW tank heaters 0.18
3N~ 400V 50Hz
Without electric heaters -
With electric heater -
With DHW tank heater -
With electric and DHW tank heaters -
YUTAKI S80
Indoor unit alone
Model Power supply Operation mode Z
max
(Ω)
RWH-4.0VNFE
1~ 230V 50Hz
Without DHW tank heater 0.31
With DHW tank heater 0.20
RWH-5.0VNFE
Without DHW tank heater 0.27
With DHW tank heater 0.18
RWH-6.0VNFE
Without DHW tank heater 0.24
With DHW tank heater 0.17
RWH-4.0NFE
3N~ 400V 50Hz
Without DHW tank heater -
With DHW tank heater 0.38
RWH-5.0NFE
Without DHW tank heater -
With DHW tank heater 0.38
RWH-6.0NFE
Without DHW tank heater -
With DHW tank heater 0.38
ELECTRICAL AND CONTROL SETTINGS