ENGLISH
7.6.2  Advanced Conguration
•  Select the advance conguration for a complete conguration.
•  Press OK button.
•  Select the controller type: 
 - Unit: the device controls the unit. 
 - Room: the device acts as a room thermostat of a zone. 
 - Unit + Room: the device controls the unit and acts as a room thermostat. 
•  Select controlled circuits by this device: Room C1, Room C2, Room C1+C2
•  Select the favourite action: Eco/Confort, Timer, Night shift.
•  Select Enabled or Disabled for European summer time.
•  Select Next and press OK button .
•  Congure circuit 1 and circuit 2 OTC: Disabled, Points, Gradient, Fix.
•  Enable or disable DHW and Swimming Pool. 
•  Select the heating source: HP only, HP + EH, HP + Boiler.
•  Congure electrical heater use: Starting or Backup.
•  Congure Boiler type: Parallel or Serial.
•  Congure Solar Combination options: Disabled, Input Demand, Total Control. (only in case DHW is enabled).
•  Enable or disable Hydraulic separator status.
•  Select Next and press OK button.
UNIT CONTROLLER
PMML0510 rev.1 - 10/2019
79