Mixed congurations (Wireless + Wired)
1- Move Unit controller to the living room (use as Unit controller + Room Thermostat)
2- Master unit controller moved to living room Zone
3- Wireless intelligent thermostat for zone 2 (ATW-RTU-07) (Receiver + Room thermostat)
OK
Indoor unit
1
Living room Zone 1
Bedroom Zone 2
Order FIRST
Type
Master
Unit
Questions Answers
Is this device attached to the unit? NO
Is this device controlling the unit? YES
Is this device installed on a controlled zone? YES, ZONE 1
How many circuits do you have? 2
Which are the emitters of circuit 1? Underoor heating
Which are the emitters of circuit 2? Underoor heating
Do you have swimming pool? NO
Do you have boiler? NO
Do you have electric backup heater? NO
Which Thermostat do you have for Circuit 2? Wireless
COMPLETED