36 37
Advanced System Set Up Advanced System Set Up [cont.]
The system will be set to its default parameters when powered on for the rst
time. The screen displays the following information in sequence and the user can
change any given value on each screen.
To change a parameter value in the program, press START/ENTER to make that
value blink. Next, change the value by pressing INC or DEC. The value will be
stored by pressing START/ENTER once.
Safet y T imer
O N 120Mi n
Res t T ime
CHG>DCH G 10Min
Capacit y Cut-Off
O N 5000mAH
Temperatur e Unit
C elsius
Tem p C ut-Of f
O N 50 ° C 1 22 ° F
This p rogram sets the maximum charge
capacity that will be supplied to t he battery
during charge. If the delta peak voltage is
not detected nor the safety timer expired by
any reason, t his feature will automatically
stop the process at t he selected capacity
value.
When you start a charge process, t he
integral safety timer automatically s tarts
running at t he s ame time. This i s
programmed to p revent overcharge the
battery i f it p roves to be faulty, or i f the
termination circuit cannot detect the battery
full. The value for the safety timer should be
generous enough to a llow a full charge of
The battery's internal chemical reaction will
cause the temperature of t he battery t o
rise. If the temperature limit is reached, the
process will be terminated.
OFF/
ON
(
100-50000 mAh)
ITEM SELECTION DESCRIPTION
OFF/
ON
(
1-720 Min)
OFF/
ON
(20 C/68 F -
80 C/176 F
)
Celsius
Fahrenheit
1-60Min
A rest t ime allowing the battery t o cool
down between charging/discharging cycle.
You can choose the temperature displayed
by Celsius or Fahrenheit as you like.
Safet y T imer
O N 120Mi n
Res t T ime
CHG>DCH G 1 0Min
Capacit y C ut-Off
O N 5000mAH
Temperatur e Unit
C elsius
Tem p C ut-Of f
O N 50 ° C 1 22 ° F
This p rogram sets the maximum charge
capacity that will be supplied to t he battery
during charge. If the delta peak voltage is
not detected nor the safety timer expired by
any reason, t his feature will automatically
stop the process at t he selected capacity
When you start a charge process, t he
integral safety timer automatically s tarts
running at t he s ame time. This i s
programmed to p revent overcharge the
battery i f it p roves to be faulty, or i f the
termination circuit cannot detect the battery
full. The value for the safety timer should be
generous enough to a llow a full charge of
the battery.
The battery's internal chemical reaction will
cause the temperature of t he battery t o
rise. If the temperature limit is reached, the
process will be terminated.
OFF/
ON
(
100-50000 mAh)
ITEM SELECTION DESCRIPTION
OFF/
ON
(
1-720 Min)
OFF/
ON
(20 C/68 F -
80 C/176 F
)
Celsius
Fahrenheit
1-60Min
A rest t ime allowing the battery t o cool
down between charging/discharging cycle.
You can choose the temperature displayed
by Celsius or Fahrenheit as you like.
ITEM SELECTION DESCRIPTION
Sensitivit y
D.Pea k
Default
NiCd
Sensitivit y
D.Pea k
Default
Default: 4mV/Cell
5-15mV/Cell
Ke y B ee p O N
Buzze r O N
OFF/ON
The beep sounds at every time t ouching
the buttons to confirm your action. T he
beep or m elody sounded at various times
during operation to a lert different m ode
changes.
Input . P owe r Low
Cut-Of f 11.0V
10.0-11.0V
This program monitors the voltage of i nput
battery. If the voltage drops below the value
you set the operation forcibly terminated to
protect the input battery.
This program is for NiMH/NiCd battery only.
When the charger detects the delta peak
value reaches the value you set, the
charger will say the battery is fully charged.
Loa d F actor y Set
E nter
Versio n
HW:1.0 0 FW : 1 .10
Press ENTER to load factory default setting.
It indicates the hardware and firmware
version.
A C Ma x P owe r Set
5 0W
0-100W
It is to set the max AC power of the present
channel. Once you set it, the another
channel will take the rest.
ITEM SELECTION DESCRIPTION
NiMH
Sensitivit y
D.Pea k
Default
NiCd
Sensitivit y
D.Pea k
Default
Default: 4mV/Cell
5-15mV/Cell
Ke y B ee p O N
Buzze r O N
OFF/ON
The beep sounds at every time t ouching
the buttons to confirm your action. T he
beep or m elody sounded at various times
during operation to a lert different m ode
changes.
Input . P owe r Low
Cut-Of f 11.0V
10.0-11.0V
This program monitors the voltage of i nput
battery. If the voltage drops below the value
you set the operation forcibly terminated to
protect the input battery.
This program is for NiMH/NiCd battery only.
When the charger detects the delta peak
value reaches the value you set, the
charger will say the battery is fully charged.
Loa d F actor y Set
E nter
Versio n
HW:1.0 0 FW : 1 .10
Press ENTER to load factory default setting.
It indicates the hardware and firmware
version.
A C Ma x P owe r Set
5 0W
0-100W
It is to set the max AC power of the present
channel. Once you set it, the another
channel will take the rest.