Questions and Answers

  • M
    mcdowellstevenAug 7, 2025
    What to do if the Hiwin EM1 Industrial Equipment motor can't rotate at all?
    • K
      Katie CampbellAug 7, 2025
      If the Hiwin Industrial Equipment motor doesn’t rotate, several issues could be the cause. First, examine the cable connected to the controller for incorrect wiring. Second, verify that there are no interfering objects causing a current overload and address any brake clamping failures. Third, review the controller's over-temperature settings. Lastly, if the issue persists, measure the insulation resistance after cooling, ensuring the stator three-phase to ground (U/V/W to PE) reads >10 MΩ at 500 VDC for 1 second at the specified temperature. Contact HIWIN if it does not reach 10 MΩ.
  • M
    Monica ThomasAug 11, 2025
    Why is my Hiwin EM1 motor experiencing unstable rotation (vibration)?
    • D
      David DeckerAug 12, 2025
      If your Hiwin Industrial Equipment experiences unstable rotation (vibration), several factors could be responsible. Begin by checking if the resistance value of phase/earth is larger than 10 MΩ to exclude insulation failure. Next, verify the installation stiffness of the encoder and ensure the encoder connection is correct. Also, inspect the controller settings and motor parameters settings.
  • B
    Barbara TranAug 16, 2025
    What causes abnormal temperature of the Hiwin EM1 Industrial Equipment motor outer casing?
    • J
      Jeanne WalkerAug 16, 2025
      If the outer casing of your Hiwin Industrial Equipment motor has an abnormal temperature, check the controller settings and motor parameters settings. Also, verify the bearing installation.
  • A
    Alyssa WallAug 20, 2025
    How to fix the wrong rotating direction of the Hiwin Industrial Equipment motor?
    • M
      Margaret RodriguezAug 21, 2025
      If the Hiwin Industrial Equipment motor rotates in the wrong direction, check the controller settings. If the settings are correct, interchange the two-phase power cable connected to the controller.
  • A
    andrewhernandezAug 25, 2025
    What to do if there is a smell of burning from Hiwin EM1?
    • J
      Jill ClarkAug 25, 2025
      If you notice a burning smell coming from the Hiwin Industrial Equipment, verify the controller settings and the motor parameters settings.
  • N
    nancy50Aug 29, 2025
    How to troubleshoot abnormal friction noise in Hiwin EM1 Industrial Equipment?
    • S
      Samantha LinAug 29, 2025
      If you hear abnormal friction noise from your Hiwin Industrial Equipment, check the brake. Also check the dynamic balance and fix any loose parts.
  • S
    stevenlyonsSep 2, 2025
    Why Hiwin EM1 motor cannot be rotated manually without connecting the controller?
    • Y
      youngalexanderSep 2, 2025
      If the Hiwin Industrial Equipment motor cannot be rotated manually without connecting the controller, it could be due to mechanical interference, so remove any interference. Alternatively, there may be a motor three-phase short circuit, which needs to be fixed.